EXHAUST INSTALLATION
The following rules must be strictly followed to obtain optimal air
extraction:
Keep the expansion pipe short and straight.
Do not reduce the size or restrict expansion pipe.
When using an expansion pipe always install the pipe pulled
taut to minimize pressure loss.
Failure to observe these basic instructions will reduce the
performance and increase noise levels of the cooker hood.
Any installation work must be carried out by a qualified
electrician or competent person.
Do not connect the ducting system of the hood to any existing
ventilation system which is being used for any other appliance,
such as a warmer tube, gas tube or hot wind tube.
The angle of the bend of the expansion pipe should be no less
than 120º; you must direct the pipe horizontally, or,
alternatively, the pipe should
go up from the initial point
and be led to an outer wall.
After the installation, make
sure that the cooker hood is
level to avoid grease
collection at one end.
NOTE: Ensure the expansion pipe selected for installation
complies with relevant standards and is fire retardant.