User Manual

15
OPERATING INSTRUCTIONS
BEFORE FIRST USE AND AFTER EVERY GAS CYLINDER CHANGE, GAS DELIVERY SYSTEM MUST BE
PURGED OF AIR BEFORE IGNITING! TO DO THIS, TURN THE CONTROL DIAL ANTI-CLOCKWISE TO THE
PILOT SETTING. PRESS THE DIAL IN AND HOLD FOR 1 MINUTE BEFORE ATTEMPTING IGNITION.
BATTERY REPLACMENT
Remove the control dial. Install 1 AA battery. The negative end of battery goes in first, then replace the control dial.
LIGHTING THE PATIO HEATER
Check all connections prior to each use.
Turn on the gas supply at source.
Press and turn the control dial anti-clockwise to the IGNITE marking.
Keep control dial depressed for up to 20 seconds until pilot is lit.
If the gas fails to ignite, press and turn the dial clockwise to OFF before
repeating the lighting steps.
Turn the dial further anticlockwise to the LOW position.
Adjust the heat by turning the dial from the LOW position to the HIGH
position as required.
In the event of the flame being disrupted (e.g. by the wind), a Flame Safety Device will automatically shut off the
gas supply within 90 seconds.
Note: it is possible to light the appliance using a long match by lighting the burner through a hole in the guard mesh.
RE-LIGHTING
Turn the Dial to the OFF position.
Wait at least 2 minutes, to let gas dissipate, before attempting to re-light pilot.
Repeat the “Lightingsteps.
TO EXTINGUISH
Hold the dial down and turn clockwise to the OFF position
Turn off the valve on the gas cylinder or the regulator after use.
Disconnect the gas bottle and allow this appliance to cool before moving the appliance.
Note: After use, some discoloration of the emitter screen is normal. Turn off the regulator after use and allow
the appliance to cool before moving.