USER MANUAL 60CM SLOPING COOKER HOOD eiQSRG60 Thank you for choosing your electriQ cooker hood. This instruction manual is designed to provide you with all required instructions related to the installation, use and maintenance of the appliance. In order to operate the unit correctly and safely, please read this instruction manual carefully before installation and usage.
CONTENTS SAFETY 3 INSTALLATION 5 OPERATION 10 FILTER INFORMATION 10 BULB REPLACEMENT 12 CLEANING AND MAINTENANCE 13 TROUBSLEHSOOTING 14 SUPPORT 14 PRODUCT FICHE 15 2
SAFETY PRECAUTIONS Whilst this product is compliant with all safety requirements, incorrect or inappropriate use can lead to both personal injury and potential damage to property. Please read the contents of this instruction booklet thoroughly before fitting or using this appliance. • The cooker hood must be installed in accordance with the installation instructions and all measurements followed. • All installation work must be carried out by a competent person or qualified electrician.
• The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels. • When the hood is vented externally and used with appliances which burn fuel (e.g. gas, oil, wood) the area must be sufficiently ventilated to ensure safe operation. Fresh air must be allowed to freely enter the room to prevent a partial vacuum. • A partial vacuum can starve the heating appliance of oxygen, impairing combustion.
PARTS LIST No.
INSTALLATION (VENT OUTSIDE) MOUNTING OF THE V-FLAP If the cooker hood does not have an assembled V-flap 1, you should mount the halfparts to its body. The images only show an example of how to mount the V-flap, the outlet may be various according to different models and configuration. To mount the V-flap 1 you should: 1. Mount two half-parts “2” into the body “6” 2. A pin 3 should be top oriented 3. The axis “4” should be inserted in the holes “5” on body 4.
INSTALLATION If you have an outlet to the outside, your cooker hood can be connected as below picture by means of an extraction duct (enamel, aluminum, flexible pipe or nonflammable material with an interior diameter of 150mm) 1. Before installation, turn the unit off and unplug it from the outlet. 2. The cooker hood should be placed at a distance of 65~75cm above the cooking surface for best effect. 3.
5. Install the outside chimney bracket onto the outside chimney with 2 ST4*8mm screws, here should be sure the inside chimney can be flexed freely. See Pic 5. 6. Fix the cooker hood with 2pcs ST4*30mm safety screws. Note: The two safety vents are positioned on the back housing, with a diameter of 6mm.Put the two chimneys onto the cooker hood, fix the outside chimney on the wall with 2pcs ST4*40mm screws and lead the expansion pipe to the outside. See pic 6. 7.
HINTS FOR EXHAUST DUCT INSTALLATION The following rules must be strictly followed to obtain optimal air extraction: • • • • • • • • Keep exhaust duct short and straight Do not reduce the size or restrict the exhaust duct When using the flexible duct always install the duct pulled taut to minimize pressure loss Failure to observe these basic instructions will reduce the performance and increase noise levels of the range hood.
OPERATION 1. Press the “Power” button, to turn the cooker hood on and off. 2. Press the “Speed” button to cycle between fan speeds, the LED display will indicate the fan speed with the numbers 1, 2 and 3. 3. Press “Lamp” button to turn the hoods light on and off. 4. Press the “Timer” button, and the cooker hood will start a countdown of 9 minutes (this will be shown on the display (9-8-7-6 etc.) When the timer has finished, the cooker hood and all functions will be turned off.
CARBON FILTER (Not Supplied) Activated carbon filter can be used to trap odors. Normally the activated carbon filter should be changed every 3 to 6 months according to your cooking habits. The installation procedure of activated carbon filter is as below: 1. Before installing or replacing the carbon filters, please disconnect mains power to the unit. 2. Press the filter lock and remove the mesh filter. 3. Turn the carbon filter on both sides of the motor anti-clockwise.
BULB REPLACEMENT The bulb must be replaced by the manufacturer, its service agent or similarly qualified persons. Always switch off the electricity supply before carrying out any operations on the appliance. When handling bulb, make sure it is completely cool down before any direct contact to hands. When handling globes hold with a cloth or gloves to ensure perspiration does not come in contact with the globe as this can reduce the life of the globe.
MAINTENANCE Before cleaning, switch the unit off and pull out the plug, or switch off at the relevant mains switch if the unit has been hard-wired in. Make sure the unit has no power being fed to it. REGULAR CLEANING Use a soft cloth moistened with warm mildly soapy water or household cleaning detergent. Never use metal pads, chemicals, abrasive material or a stiff brush to clean the unit. STAINLESS STEEL The stainless steel must be cleaned regularly (e.g.weekly) to ensure long life expectancy.
TROUBLESHOOTING FAULT Light on, but fan does not work Both light and fan do not work Excessive Vibration Suction performance not good CAUSE The fan blade is jammed. The motor is damaged. Light bulb blown Power cord loose The fan blade is damaged. The fan motor is not fixed tightly. 1 Grease filters clogged 2 Distance between the unit and the cooking plane too great. SOLUTION Switch off the unit. Repair to be carried out by qualified service personnel only. Replace the bulb with correct rating.
PRODUCT FICHE Symbol Model identification Annual Energy Consumption Time increase factor Fluid Dynamic Efficiency Fluid Dynamic Efficiency class Energy Efficiency Index Value eiQSRG60 AEChood 26.3 f 1.5 FDEhood 14.