Instruction Manual

Page 5 of 24
INSTALLING WITHIN A BATHROOM
If the appliance is to be fitted within a bathroom, a good understanding of the zoning within
bathrooms is required to ensure the unit is mounted in a safe position. The appliance is rated as
IPX4 and should be installed outside of Zones 0 -2. We would advise when the unit is fitted within
a bathroom, the plug is removed from the unit, and a suitable fused spur is installed in accordance
with BS 7671. In addition, when used in a bathroom, it must be protected by a suitable RCD to
prevent the risk of electric shock.
Zone 0:
The interior of the bathtub or shower basin.
Zone 1:
The area around the bathtub or shower basin up to a height
of 2.25m above the floor
Zone 2:
The area stretching to 0.6m outside the bath or shower and
above the bath or shower if over 2.25m