USER MANUAL electriQ PORTABLE AIR CONDITIONER P12C 12,000 BTU P15C 14,000 BTU Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our page www.electriQ.co.
CONTENTS SAFETY INFORMATION 2 FEATURES 5 PARTS LIST 5 INSTALLATION 6 OPERATION 8 REMOTE CONTROL 9 EMPTYING THE INTERNAL WATER TANK 10 CLEANING AND MAINTENANCE 11 TROUBLESHOOTING 12 ERROR CODES 12 SUPPORT 13 TECHNICAL SPECIFICATION 14 2
SAFETY INSTRUCTIONS Important! • Carefully read the instructions before operating the unit • This appliance is for indoor use only. • Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. • Installation must be in accordance with regulations of the country where the unit is used. • If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician. • This air conditioner has been tested and is safe to use.
• R290 refrigerant gas complies with European environmental directives. • R290 has a low GWP (Global Warming Potential) of 3. • The air conditioners contain around 280 g of R290 refrigerant gas. • Do not use or store in an unventilated space with an area smaller than 13.4 m2 per unit.
FEATURES • • • • • • 3 in 1 Cooling, Fan, Dehumidifier. The P12C is great for Rooms up to 30 m2 and the P15C for rooms up to 38m2. 3 speed fan: Balancing quiet operation with performance. 24 Hours Start / Stop Timer. Digital Thermostat. Remote Control. Castors for Enhanced Portability.
INSTALLATION WARNING: Before using this unit, please keep it upright for at least 3-4 hours. This unit can easily be moved from one room to another. While moving the unit please note that it must always be kept upright and then placed on an even surface. 1. Attach the fishtail connector to the end of the hose, by extending the end and twisting until firmly attached (At least 3 full rotations). 2.
NOTES: • • • • • The window kit is only designed to be installed with sliding or sash windows or doors. The window kit is not designed or to be used with any other style of windows. The fish tail adaptor can be used without the slide bar with most windows / doors. When using the air conditioner ensure that the opening left around the fishtail is as small as possible as the cooling will be less efficient. The best form of installation is through a wall duct.
OPERATION Press the POWER button to turn the unit ON or OFF. Press the MODE button to cycle between the 3 modes, the indicator for the selected mode will be illuminated. COOL: The room is cooled with the cold air expelled through the front air outlet while hot air is expelled through the vent pipe. The desired room temperature can be set between 16 and 32 degrees using the + and – buttons, and the fan speed can be changed using the SPEED button. FAN: The fan speed can be changed pressing the SPEED button.
REMOTE CONTROL POWER TEMP + POWER TEMP - SPEED MODE SLEEP Press to turn the unit on or off. Press to decrease the desired temperature or TEMP timer duration. Press to increase the desired temperature or TEMP + timer duration. SPEED Press to change between the three fan speeds. SLEEP Press the sleep button to enter sleep mode. Press to change between Auto, Cool and Fan MODE modes. NOTE: The design of the remote may vary from the diagram, due to continuous product improvement.
EMPTYING THE INTERNAL WATER TANK MANUAL DRAINAGE: When the internal water tank is full the unit will stop working. Shut off the unit and unplug. Try not to move the model abruptly as this may cause the water in the internal tank to spill out. Place a tray under the lower water plug or place the unit in a drainage area. Unscrew the drain plug cap and remove the rubber stopper - water will drain from the internal tank. Put the rubber stopper back and screw the drain plug cap back into place.
CLEANING AND MAINTENANCE PLEASE TURN OFF THE UNIT AND UNPLUG FROM THE MAINS BEFORE CLEANING OR PERFORMING ANY MAINTENANCE CLEAN THE SURFACE Clean the surface of the machine with a wet soft cloth. Do not use chemicals, such as benzene, alcohol, gasoline, etc; otherwise, as this may cause damage to the surface and or the internal workings of the machine AIR FILTER CLEANING If the filter screen is clogged with dust, the effectiveness of the air conditioner is reduced.
TROUBLESHOOTING Do not repair or disassemble the air conditioning. Unqualified repair will invalidate the warranty and may lead to failure, causing injuries and property damage. Only use it as directed in this user manual and only perform operations advised here. Problems The air conditioner does not work. The cooling effect is not good Reasons Solutions There is no electricity. Turn it on after connecting it to a socket with electricity. The display shows "E4". Discharge the water inside.
APPENDIX Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils.
TECHNICAL DATA Model Cooling capacity: Input power: Fan P12C 12,000 BTU 1300 W P15C 14,000 BTU 1500 W AC motor with 3 fan speeds. Air flow volume: 420 m³/h Input current: 5.65 A 6.5 A Refrigerant: R290/280g Sound power level: 56 dB(A) Thermostat: 16-32oC Maximum working pressure of 1.0/3.5 MPa suction/exhaust side: Maximum Allowable Pressure 3.5 Mpa Power Supply: AC 230V/50 Hz Net Weight: 27.5 kg 28.