USER MANUAL PORTABLE AIR CONDITIONER WITH HEATPUMP P16HP / P18HP Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our page www.electriQ.co.uk for our entire range of Intelligent Electricals.
CONTENTS SAFETY INSTRUCTIONS 3 FEATURES AND PARTS LIST 5 INSTALLATION 7 OPERATION AND SETTINGS 9 WATER-DRAINAGE 11 MAINTENANCE 12 TROUBLESHOOTING 13 APPENDIX 14 Page 2 of 15
SAFETY INSTRUCTIONS IMPORTANT! • Carefully read the instructions before operating the unit • This appliance is for indoor use only. • Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. • Installation must be in accordance with regulations of the country where the unit is used. • If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician. • This air conditioner has been tested and is safe to use.
• • • • • • • • • • • R290 refrigerant gas complies with European environmental directives. R290 has a low GWP (Global Warming Potential) of 3. The P16HP contains about 225 g of R290 refrigerant gas, and the P18HP contains about 300g of R290 refrigerant gas. Do not use or store in unventilated spaces with an area smaller than 10.8 m 2 per unit for P16HP and 14.4 m2 per unit for P18HP.
FEATURES AND PARTS LIST FEATURES ⚫ Full climate control, cooling, heating, fan and dehumidifier ⚫ Self-evaporative system - no external water tank needed ⚫ Powerful but compact ⚫ LED screen, indicates temperature and operation mode ⚫ Enhanced design with hot air outlet positioned higher – This allows for improved performance with the use of a short hose ⚫ 24 hour programmable timer function – Allows you to choose when the unit operates.
PARTS LIST Control Panel Rear cover Air Inlet SIDE VIEW FRONT VIEW REAR VIEW Castor Plug ACCESSORIES Exhaust Hose Remote Control Fishtail Connector Exhaust hose connector Slide Bar Drain Pipe Please Note: The design of the accessories may change as part of our continual product improvement.
INSTALLATION Warning:Before using this unit, please keep it upright for at least 3-4 hours. This unit can easily be moved from one room to another. While moving the unit please note that it must always be kept upright and then placed on an even surface. 1. Assemble the fishtail adaptor on to the hose, by extending the end of the hose and twisting the fishtail into position (At least 3 full rotations) 2.
INSTALLATION OF WINDOW KIT 1. Partially open the window and then fix the slide bar into the opening in the window, by putting it into position before closing the window onto it to seal the gap. 2. Push the fishtail adaptor into the slot in the slide bar Note: The slide bar is only designed to be installed with sliding or sash windows or doors. The slidebar is not designed or to be used with any other style of window. However the fish tail adaptor can be used with most windows /doors.
OPERATION AND SETTINGS CONTROL PANEL & FUNCTION POWER BUTTON Press to turn unit “ON” or “OFF” MODE Pressing this button will select between the Cooling Dehumidify modes. , Heating , Auto, Fan and COOLING MODE: Cold air will be expelled through the top of the unit and hot air will be expelled through the vent hose. HEATING MODE: Hot air will be expelled through the top of the unit and cold air will be expelled through the vent hose. Continuous drainage should be set up for the moisture collected.
SLEEP MODE Press the SLEEP button to enter sleep mode, the default fan speed is low and the Sleep mode indicator led will illuminate. When the sleep mode is turned on: After one hour the set temperature will increase by 1 degree Celsius, after another hour the set temperature will increase by another degree, and will then remain set at that temperature. Please note: • Sleep mode cannot be used in dry and fan modes. • If internal tank becomes full, the machine will turn off and sleep mode will be cancelled.
REMOTE CONTROL 1. POWER – ON/OFF Switch 2. 3. MODE – Operation Mode TIMER – Timer Mode 4. SPEED – Fan Speed Selector 5. 6. TEMP+ - Temperature Up TEMP- – Temperature Down 7. SLEEP 8. SWING The functions on the remote are the same as those on the main control panel WATER-DRAINAGE MANUAL DRAINAGE: 1. When the internal water tank is full the unit will stop working and the TANK FULL indicator will illuminate. 2. Shut off the unit and unplug.
MAINTENANCE CLEANING Please shut off the unit and unplug from the mains before cleaning or performing any maintenance CLEAN THE SURFACE Clean the plastic housing with a duster or a soft wet cloth. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage. AIR FILTER CLEANING a) Clean the air filters every 2 weeks. If the air filter is blocked with dust, the unit’s performance will be significantly affected.
TROUBLESHOOTING Do not repair or disassemble the unit by yourself, unauthorized repair attempts will invalidate the warranty and may cause bodily harm. Problem The unit does not work Reasons Solutions No power supply Power-on and turn on the unit.
APPENDIX Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils.
electriQ UK SUPPORT www.electriQ.co.uk/support Please, for your own convenience, make these simple checks before calling the service line. If the unit still fails to operate call: 0330 390 3061 or complete the online form 1. Has the unit been standing upright for at least 2 hours? 2. Is the unit plugged into the mains? 3. Is the fuse OK? 4. Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit. 5. Check if the water tank is full.