PLM12000HP PORTABLE AIR CONDITIONER WITH HEAT PUMP USER MANUAL Thank you for choosing ElectrIQ. Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our page www.electrIQ.co.
CONTENTS 1. .SAFETY INSTRUCTIONS ………………………………….. 3 2. .FEATURES AND PARTS LIST ………………………….... 4 3. .INSTALLATION …………………………………. …………. 6 4. .OPERATION AND SETTINGS …………………………….. 8 5. .WATER-DRAINAGE …………………………………………. 11 6. .MAINTENANCE ……………………………………………… 12 7. .TROUBLE SHOOTING …………………………………. …. 13 8. .APPENDIX …………………………………………………….
SAFETY INSTRUCTIONS Important! • Carefully read the instructions before operating the unit • This appliance is for indoor use only. • Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. • Installation must be in accordance with regulations of the country where the unit is used. • If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician. • This air conditioner has been tested and is safe to use.
FEATURES AND PARTS LIST 1. Features Self-evaporative system - no external water tank needed Slim oval design - designer inspired luxury model Louvres outlet closes automatically when shutting down the unit, this prevents dust and dirt entering the machine. Bright LCD screen, indicates temperature and operation mode Remote control and power plug can be stored at the rear of the unit after use.
2. Parts list: : ① ② ③ ④ ⑨ ⑥ ⑩ ⑤ ⑧ 13 14 1. Top cover 2. Air outlet grille 3. Control panel 4. Front cover 5. Castor 6. Handle 7. Power cord 8. Drain port 12 15 9. 10. 11. 12. 13. 14. 15. 16.
INSTALLATION 1. Installation Warning: :Before using this unit, please keep it upright for at least 3-4 hours. This unit can easily be moved from one room to another. While moving the unit please note that it must always be kept upright and then placed on an even surface. 1. Assemble hose adaptor: 2. Prepare both parts of hose adaptor and clip them together Note: Do not push too hard as this may cause damage. 3. Assemble the exhaust hose 4.
. Make sure the unit is upright and there are no obstructions to the air inlets and outlet grills 8. Fix the other end of the hose to the air-outlet window kit Note: The window kit is only designed to be installed with sliding or sash windows or doors. The window kit is not designed or to be used with any other style of windows. However the fish tail adaptor can be used with most windows / doors. When using the cooling mode ensure that the opening left is as small as possible.
OPERATION AND SETTINGS This portable air conditioner boasts four functions: cooling, heating, dehumidifying and fan. The fan has three speeds: high, medium and low Temperature range settings are: 18--300C The unit will also display operating function, temperature, fault diagnostic and protective functions on the LCD screen. 1. Control instruction: : Control panel: : Timer Mode Sleeping Display Area Swing Fan Speed Max cool On/Off Up IR Signal Receptor Down 1.
1.6 Up and Down button: set temperature and timer . In cooling and heating mode, the temperature can range from 18- 30℃ and Pressing 1.7 Sleep mode key buttons simultaneously, shifts between ℃ and ℉. : In cooling or heating mode, press the key and the unit will go into sleeping mode. LCD will show Press again to cancel. 1.8 Swing button cancel. 1.
2. Remote control Drawing of Remote Control panel: LOCK LOCK RESET Remote control for Cool only RESET Remote control for Cool & Heat 1.Power :Press this key to turn the unit on/off. 2.Mode :Press this key to choose cooling, heating, dehumidifying or fan mode 3.Up :Press this key to turn up the temperature or adjust time. 4.Down :Press this key to turn down the temperature or adjust time. 5. .Fan :Press this key to set low/medium/high fan speed. 6.
3. Multi protective function 3.1 Anti-freezing protecting control: When the ambient temperature is low while in Cooling Mode, the compressor and water motor will stop working if the copper coil temperature reaches <2℃ for over 20 seconds. When the copper coil temperature increases to >8℃, the protection will be stopped automatically. 3.
WATER-DRAINAGE 1. Manual drainage: 1.1 When the internal water tank is full the unit will stop working. 1.2 Shut off the unit and unplug. Try not to move the model abruptly as this may cause water to spilt out from internal water tank. 1.3 Place a tray under the water plug. 1.4 Screw off the water plug and unplug the water blocker - water will drain from the container. 1.5 Put the water blocker back and screw the water plug back into place 2. Continuous drainage: 2.
Maintenance Cleaning. Please shut off the unit and unplug from the mains before cleaning or performing any maintenance Clean the surface Clean the plastic housing with a duster or a soft wet cloth. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage. Air filter cleaning a) Clean the air filters every 2 weeks. If the air filter is blocked with dust, the unit’s performance will be significantly affected.
Trouble Shooting Do not repair or disassemble the unit by yourself, unauthorized repair attempts will invalidate the warranty and may cause bodily harm. Trouble Reason Solution No power supply Power-on and turn on the unit. The unit does Water-full indicator illuminated Drain the internal water tank Timer function is active Cancel Timer function not work Room temperature too low or Use only in ambient temperatures too high between 7-40℃ In direct sunlight Windows or doors open.
APPENDIX Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils.
ElectrIQ UK SUPPORT www.ElectrIQ.co.uk/support Please, for your own convenience, make these simple checks before calling the service line. If the unit still fails to operate call: 0871 620 1057 or complete the online form 1. Has the unit been standing upright for at least 2 hours? 2. Is the unit plugged into the mains? 3. Is the fuse OK? 4. Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit. 5. Check if the water tank is full.