USER MANUAL ELECTRIC DESIGNER RADIATOR WITH SMART APP HS10-600-0.6DGW HS10-600-0.6WW HS10-600-0.6LGW HS17-600-1.2DGW HS17-600-1.2WW HS17-600-1.2LGW HC18-400-1.2WW HC26-400-1.2WW VD6-1600-1.2LGW VD6-1600-1.2WW VD4-1600-1.2WW VD4-1600-1.2LGW VD6-1600-1.2DGW VD4-1600-1.2DGW VS6-1600-1LGW VS6-1600-1WW VS6-1600-1DGW VS4-1600-1WW VS4-1600-1DGW VSM6-1800-1.2LGW VSM6-1800-1.2DGW VSM6-1800-1.
CONTENTS SAFETY INSTRUCTIONS PARTS SUPPLIED INSTALLING WITHIN A BATHROOM INSTALLATION OF HEATING ELEMENT WALL MOUNTING OPERATION SETTING THE TIME PROGRAMMING THE TIMER CONNECTING YOUR APPLIANCE TO WI-FI REGISTER THE APP CREATING ROOMS QUICK CONNECTION AP MODE CONNECTION USING THE APP HOME SCREEN DEVICE SCREEN SMART SCENES AUTOMATION CONNECTION TROUBLESHOOTING MAINTENANCE TROUBLESHOOTING TECHNICAL DATA SUPPORT PRODUCT FICHE Page 2 of 26 3 4 5 6 7 8 9 9 10 11 12 13 14 15 15 16 17 18 19 20 20 21 22 23
SAFETY INSTRUCTIONS • • • • • • • • • • • • • • • • • • • • • IMPORTANT: Carefully read the instructions before operating the unit. This appliance is for indoor use only. Rating: This unit must be only connected to a 220-240 V / 50 Hz earthed outlet. Installation must be in accordance with the regulations of the country where the unit is used. If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician.
• Do not use the appliance for anything other than its intended use. It is designed for domestic indoor use only. • There may be a trace of odour during the first few minutes of initial use, or after a period of storage. This is normal and will quickly disappear. • This appliance has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or any flammable liquids are used or stored.
INSTALLING WITHIN A BATHROOM If the appliance is to be fitted within a bathroom, a good understanding of the zoning within bathrooms is required to ensure the unit is mounted in a safe position. The appliance is rated as IPX4 and should be installed outside of Zones 0 -2. We would advise when the unit is fitted within a bathroom, the plug is removed from the unit, and a suitable fused spur is installed in accordance with BS 7671.
INSTALLATION OF HEATING ELEMENT IMPORTANT: Before drilling, ensure that no wires or pipelines are behind the wall to prevent damage. IMPORTANT: This heater is heavy. Two people are recommended for installation. First ensure that you have all the correct parts needed for installation of the heating element: • Heating Element • PTFE Tape • Spanner • The heating element is designed to be fitted into the bottom of the unit and can be fitted into either the left or right port.
Thread Page 7 of 26
WALL MOUNTING NOTE: Depending on your wall type alternative fixings may be required to secure the heater to your wall. Step 1 Step 2 Measure the distance between the two columns that you will be hanging your heater from on the top of the heater and the two ends on the bottom of the rail. Then measure the distance vertically between the top and bottom holes. Make a note of the measurement, and mark four points on the wall that distance apart. Use a spirit level to ensure that they are level.
OPERATION Display: Displays the current time, temperature and function. Power: Press once to turn the unit on. Press again to turn the unit off. Increase: Use the increase button to increase the value of the selected function. Press and hold for 10 seconds to restore the unit to its factory settings. Function: Press to cycle through the unit’s functions. Press and hold when the unit is shutdown to enter the Wi-Fi connection mode. Please see “Wi-Fi Set-Up” on page 10 for more information.
SETTING THE TIME When the unit is powered on, press the function button until the Timer image is displayed on screen. Then, press and hold the function button to set the time. Use the increase and decrease buttons to adjust the hour value between 0-23 hours. After you have set the hours, press the function button once to set the minutes. Use the increase and decrease buttons to adjust the minutes between 0 and 59 minutes. Press the function button again to confirm the time and begin programming the timer.
CONNECTING THE APPLIANCE TO WIFI DOWNLOAD THE APP TO YOUR PHONE Download the” TUYA SMART” app, from your chosen app store, using the QR codes below, or by searching for the app in your chosen store. ANDROID IOS MODES AVAILABLE FOR SETUP It is recommended to use Bluetooth connection to connect your unit to Wi-Fi. This is the easiest connection method and will ensure that no time is wasted in getting to use your new heater to its fullest potential.
REGISTER THE APP 1. Press on the register button at the bottom of the screen. 4. A verification code will be sent by the method selected in step 3. Enter the code into the app. 2. Read the Privacy policy and press the Agree Button. 3. Enter your email address or phone number and press continue to register. 5. Type in the password you would like to create. This needs to be 6-20 characters, with letters and numbers. 6. The app is now registered. It will automatically log you in following registration.
SETTING UP YOUR HOME WITHIN THE APP TUYA is designed so it can work with a large number of compatible smart devices within your home. It can also be set up to work with multiple devices within different houses as such during the setup process, the app requires that different areas are created and named to allow easy management of all your devices. When new devices are added, they are assigned to one of the rooms you have created. CREATING ROOMS 1. Press on the ADD HOME button. 2.
CONNECTING USING THE BLUETOOTH CONNECTION METHOD Before initiating the connection, make sure your mobile phone has Bluetooth enabled and that the unit is plugged in. Also ensure your phone is connected to the WiFi network. (We advise turning mobile data off during setup). 1. Open app and enter the home screen. Turn the unit on and on the app, press add device. 2. Select your Wi-Fi and enter 3. Your device will then begin to connect. Once successfully your Wi-Fi password, this is connected, press next.
CONNECTING USING AP MODE (ALTERNATIVE METHOD) Before initiating the connection, make sure the unit is in standby mode, with AP mode activated. If not follow the instructions for changing the WiFi connection mode. Also ensure your phone is connected to the WiFi network. (We advise turning mobile data off during setup) 1. Open app and press “+” to add device, or use the add device button 2. When the devices in connection mode, it will appear at the top. Press add to add the device. 3.
CONTROLLING YOUR APPLIANCE THROUGH THE APP THE HOME SCREEN Each device has its own entry on the home screen to allow the user to either quickly turn the unit on or off, or to enter the device screen to make other changes. Voice Control: Press to give verbal instructions for operation. Add Device: Add a device to the app, and go through the setup process.
DEVICE SCREEN The device screen is the main control screen for the heater, providing access to the controls to amend the functions and settings. Device Profile: Use to change the name of the heater Device Name Back: Returns to the Home Screen Increase Desired Temperature Desired Temperature: Displays what has been set as the target room temperature. Temperature range 15-70⁰C SETTINGS: Child lock – Turn the child lock on/off. All functions will be locked until child lock is disabled.
SMART SCENES Smart Scenes is a powerful tool providing the option to customize the operation of the air heater based both on conditions within the room and outside influences. This gives the user the option of specifying much more intelligent actions. These are split into two categories Scene and Automation. SCENE Scene allows for a one touch button to be added to the Home Screen. The button can be used to change a number of settings in one go, and can change all the settings within the unit.
AUTOMATION Automation allows an automatic action to be set up for the device. This can be triggered by the Time, and a range of other influences, depending what other TUYA enabled devices you have on the network. 1. Press on the Scene tab at the bottom of the Home screen 2. Press on the Automation tab at the top of the screen. 3. Press on the + at the top of the screen or press on Add Automatic Action 4.
PROFILE TAB The profile tab gives you the option to edit both your detail, and use the added features of the unit. HOME MANAGEMENT Home Management proves options for managing your TUYA account, giving options such as adding a home, adding and removing rooms, and sharing devices with family.
MAINTENANCE CLEANING AND STORAGE ATTENTION: Please shut off the unit and unplug from the mains before cleaning or performing any maintenance. Cleaning the surface Clean the heater with a duster or a soft wet cloth. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage. Make sure no water enters the control panel or gaps in the casing. Do not run the unit until completely dry.
TECHNICAL DATA MODEL HS10-600-0.6DGW HS10-600-0.6WW HS10-600-0.6LGW VSTR9-650-0.6WW VSTR9-650-0.6DGW VSTR9-650-0.6BSW VS6-1600-1LGW VS6-1600-1WW VS6-1600-1DGW VS4-1600-1DGW VSTR12-1200-1DGW VS4-1600-1LGW VS4-1600-1WW VSM6-1800-1.2DGW VD4-1600-1.2DGW VD4-1600-1.2WW VD4-1600-1.2LGW VD6-1600-1.2DGW VD6-1600-1.2WW VD6-1600-1.2LGW HC26-400-1.2WW HC18-400-1.2WW HS17-600-1.2DGW HS17-600-1.2LGW HS17-600-1.2WW VSTR32-1800-1.2WW VSM6-1800-1.2WW VSM6-1800-1.
electriQ UK SUPPORT www.electriQ.co.uk/support Please, for your own convenience, make these simple checks before calling the service line. If the unit still fails to operate call: 0330 390 3061 or complete the online form 1. Is the unit plugged into the mains? 2. Is the fuse OK? 3. Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit. Office hours: 9AM - 5PM Monday to Friday www.electriQ.co.
PRODUCT FICHE HS10-600-0.6DGW HS10-600-0.6WW HS10-600-0.6LGW VSTR9-650-0.6WW VSTR9-650-0.6DGW VSTR9-650-0.6BSW Item Symbol Value Unit Heat Output Item Unit Type of heat input, for electric storage local space heaters only (select one) Nominal heat output Pnom 0.6 kW manual heat charge control, with integrated thermostat No Minimal heat output Pmin 0.6 kW manual heat charge control with room and/or outdoor temperature feedback No Maximum continuous heat output Pmax 0.
VS6-1600-1LGW VS6-1600-1WW VS6-1600-1DGW VS4-1600-1DGW VSTR12-1200-1DGW VS4-1600-1LGW VS4-1600-1WW Item Symbol Value Unit Heat Output Item Unit Type of heat input, for electric storage local space heaters only (select one) Nominal heat output Pnom 1.0 kW manual heat charge control, with integrated thermostat No Minimal heat output Pmin 1.0 kW manual heat charge control with room and/or outdoor temperature feedback No Maximum continuous heat output Pmax 1.
VSM6-1800-1.2DGW HC26-400-1.2WW HC18-400-1.2WW HS17-600-1.2DGW HS17-600-1.2LGW HS17-600-1.2WW VSTR32-1800-1.2WW VSM6-1800-1.2WW VSM6-1800-1.2LGW VD4-1600-1.2DGW VD4-1600-1.2WW VD4-1600-1.2LGW VD6-16001.2DGW VD6-1600-1.2WW VD6-1600-1.2LGW Item Symbol Value Unit Heat Output Item Unit Type of heat input, for electric storage local space heaters only (select one) Nominal heat output Pnom 1.2 kW manual heat charge control, with integrated thermostat No Minimal heat output Pmin 1.