MANUAL ADDENDUM Loop Based Digital Recorder
MANUAL CHANGES CHANGES ON PAGE 7 (TEXT CHANGE)... KEY FEATURES OF REPEATER Compact Flash Cards (CFC) are Repeater's main storage mechanism. They supplement Repeater's internal 8MB of memory with up to 512MB of additional storage space. Loops on the CFC are in .WAV file format. With the addition of an inexpensive CFC USB card reader, you can export loops and tracks from Repeater to your PC without any special software. CHANGES ON PAGE 9 (TEXT CHANGE)...
Repeater can begin recording when it hears something, rather than in response to a button being pressed. Here is how to do it: ¥ Press and hold Stop and then press Record. This puts the unit into audio triggered mode. ¥ Whilst record is held down the trigger level can be adjusted using the tempo encoder. ¥ The audio trigger is activated when Record is released. This is indicated by the record button LED flashing.
PITCH SHIFTING You can alter the pitch of your tracks by one octave up or two octaves down. ¥ Press the Pitch button and the display will change to show pitch information in semi-tones for the selected track(s). ¥ Deselect any tracks you donÕt want to Pitch Shift using the Track Select buttons. Editing one track at a time displays the pitch shift amount with a finer resolution. ¥ Use the Tempo knob to change the pitch in cents (100th of semitone) intervals.
Advanced MIDI RT tweaking In some situations it may be desirable for Repeater to NOT send out MIDI RT start, stop and SPP messages. The output of these messages can be inhibited/enabled by sending Repeater the Inhibit MIDI RT Control CC message. When syncing via MIDI, it may be necessary to tell Repeater where the downbeat is. This is done by pressing the tap tempo button. CHANGES ON PAGE 35 (TEXT ADDED)...
CHANGES ON PAGE 37 (TEXT CHANGED)...
Tap Tempo Loop Select Up Loop Select Down Dry Mute* Erase Loop* Audio Trigger Record* 0 0 0 Off N/A N/A 12 4 5 22 N/A 23 68 96 97 107 108 92 Advance Track Select* Tracks 1&2 Level /Mute* Tracks 3&4 Level /Mute* Inhibit MIDI RT Start/Stop Output* Internal Loop Select PC* CFC Loop Select PC* N/A N/A N/A Off 24 25 26 N/A 109 110 111 112 N/A N/A 48 - 63 64 - 127 N/A N/A 0 - 127 0 - 127 0 - 127 0 - 127 0 - 127 64-127 (Press) 64-127 (Action) 64-127 (Action) 0-63 (Off) 64-127 (On) Value of 123 erases