At machine set up, a Designated Person
2
should test each emergency stop push button for proper machine shutdown
response. A Designated Person should check the emergency stop buttons for proper operation, physical damage, button
looseness, and excessive environmental contamination. This should take place on a periodic schedule determined by the
user, based on the severity of the operating environment and the frequency of switch actuations. Adjust, repair, or replace
components as needed. If inspection reveals contamination on the switch, thoroughly clean the switch and eliminate the
cause of the contamination. Replace the switch and/or appropriate components when any parts or assemblies are
damaged, broken, deformed, or badly worn; or if the electrical/mechanical specifications (for the environment and
operating conditions) have been exceeded. Always test the control system for proper functioning under machine
control conditions after performing maintenance, replacing the emergency stop device, or replacing any component of the
device.
Specifications
Housing / Button
Polycarbonate / Polyamide
Threaded base has M30 x 1.5 external threads; Max. Tightening
Torque: 4.5 N·m (40 in·lbf)
Operating Conditions
Temperature: –25 °C to +55 °C (−13 °F to +131 °F)
Humidity: 45% to 85% RH (no condensation)
Environmental Rating
IP65 (IEC60529)
Insulation Resistance
100MΩ minimum (500 V dc megger)
Impulse Withstand Voltage
2.5 kV
Pollution Degree
3
Output Configuration
See Installation and Maintenance on page 2
Overvoltage Category
II
Contact Material/Bounce
3
Gold plated silver / 20 ms
Electrical Life
100,000 operations minimum, 250,000 operations minimum at 24 V
AC/DC, 100 mA
Mechanical Life
250,000 operations
Shock Resistance
Operating extremes: 150 m/s
2
(15G)
Vibration Resistance
Operating extremes: 10 to 500Hz, amplitude 0.35 mm acceleration
50 m/s
2
LED Color
Yellow - 590 nm, Red - 618 nm
LED Flash Rate
1.6 Hz at 50% duty cycle
LED Voltage/Current
SSA-EB1..LYR-.., SSA-EB1(2)..LXR-.., and SSA-EB1.. L-..: 12 to 30
V dc; 120 mA at 12 V dc, 65 mA at 24 V dc, 60 mA at 30 V dc
SSA-EB1..LGR-..: 12 to 30 V dc; 135 mA at 12 V dc, 75 mA at 24 V
dc, 70 mA at 30 V dc
Electrical Rating
Minimum load: 1 mA at 5 V ac/dc
SSA-EB1(2)xx-xxECQ8: 2A at 60 V ac / 75 V dc maximum
UL Applications: 1.5 A at 250 V ac, 1 A at 30 V dc (pilot duty)
CE Applications: AC-15: 1.5 A at 250 V ac, DC-13: 1 A at 30 V dc
Rated Insulation Voltage (Ui)
60 V ac / 75 V dc
Rated Current (Ith)
2A
B10d
100,000 (based on ISO13849-1(2006))
Design and Application Standards
Compliant with EN/IEC 60497-1 / -5-1, ISO 13850, ANSI B11.19 ,
ANSI NFPA79, IEC 60204-1
Date code format (U.S. Standard Format)
YYWWX: 2-digit year, 2-digit week, "X” internal code
Certifications
2
A Designated Person is identified in writing by the employer as being appropriately trained to perform a specified checkout procedure. A Qualified Person
possesses a recognized degree or certificate or has extensive knowledge, training, and experience to solve problems relating to the emergency stop
installation.
3
When the button is reset, the normally closed contacts will chatter. When pressing the button, the normally open contacts will chatter. When designing a
control circuit, take the contact chatter time into consideration. Do not expose the switch to external shocks, otherwise the contacts will bounce.
SSA-EB Series Lighted Emergency Stop Push Buttons
P/N 162754 Rev. D www.bannerengineering.com - Tel: +1-763-544-3164 5