Datasheet
Rated Operating Current and Voltage (Ue)
Safety Contact (N.C.) 30 V 60 V ac/75 V dc
AC 50/60 Hz
Resistive Load (AC-12) - 2 A
Inductive Load (AC-15) - 2 A
DC
Resistive Load (DC-12) 2 A 0.4 A
Inductive Load (DC-13) 1 A 0.22 A
Auxiliary Output (N.O.) 30 V 60 V ac/75 V dc
12 to 30V dc (from supply pin 2)
Resistive Load (DC-12) 0.25 A n.a.
Inductive Load (DC-13) 0.25 A n.a.
The operating current is classified according to JIS C 8201-5-1-1999 making and breaking capacities and are measured at resistive/inductive load
types specified in IEC 60947-5-1. See "Electrical Rating" above for specific model and UL/CE maximum ratings.
Dimensions
All measurements are listed in millimeters (inches), unless noted otherwise.
19
[.75]
59,5
[2.34]
33
[1.30]
119,8
[4.72]
80
3.15[ ]
M30 X 1.5
M12 X 1
1/2 -14 NPSM
5,0
[0.19]
32,8
[1.29]
30,0
[1.19]
12,7
[0.50]
Preferred Alternative
10,0
[0.38]
Hole Dimensions
Figure 2. Standard 40 mm Pushbutton
19
[.75]
59,5
[2.34]
33
[1.30]
119,8
[4.72]
80
3.15[ ]
M30 X 1.5
M12 X 1
1/2 -14 NPSM
5,0
[0.19]
32,8
[1.29]
30,0
[1.19]
12,7
[0.50]
Preferred Alternative
10,0
[0.38]
Hole Dimensions
Figure 3. Large 60 mm Pushbutton
SSA-EB Series Lighted Emergency Stop Push Buttons
6 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 162754 Rev. D