Specifications
Place projections
on contact block
Press on the
terminal cover
TOP Mark
Slots
3. Press the SSA-EB1-TC terminal cover toward the contact block.
Remove the SSA-EB1-TC Terminal Cover
1. Pull out the two latches on the top of the SSA-EB1-TC terminal cover. Do not exert excessive force on the latches, or the latches may
break.
Projections
(pull)
2. Remove the SSA-EB1-TC terminal cover.
Install the IP20 Fingersafe SSA-EB1-FSTC Terminal Cover
After installation, the SSA-EB1-FSTC terminal cover cannot be removed.
With the SSA-EB1-FSTC terminal cover installed, crimping terminals cannot be used. Use solid wires.
The SSA-EB1-FSTC terminal covers cannot be installed after wiring.
Make sure that the SSA-EB1-FSTC terminal cover is securely installed. IP20 cannot be achieved when installed loosely, and electric
shocks may occur.
1. Align the TOP mark on the cover with the TOP mark on the contact block.
2. Press the cover toward the contact block.
TOP Mark
Press
TOP Mark
WARNING: Shock Hazard and Hazardous Energy
Always disconnect power from the safety system (for example, device, module, interfacing,
etc.) and the machine being controlled before making any connections or replacing any com-
ponent.
Electrical installation and wiring must be made by Qualified Personnel and must comply with the rele-
vant electrical standards and wiring codes, such as the NEC (National Electrical Code), ANSI
NFPA79, or IEC 60204-1, and all applicable local standards and codes.
Lockout/tagout procedures may be required. Refer to OSHA 29CFR1910.147, ANSI Z244-1, ISO
14118, or the appropriate standard for controlling hazardous energy.
SSA-EB Series Emergency Stop Push Buttons
6 www.bannerengineering.com - tel: 763-544-3164 P/N 168349_web
Rev. B