Specifications
Specifications
Button/Locking Collar
Polyamide/Aluminum
Operating Temperature
Non-illuminated: –25 to +60°C (-13 to +140°F)
Illuminated: –25 to +55°C (-13 to +131°F)
Environmental Rating
Actuator: IP65 (IEC60529)
Terminal: IP20 with SSA-EB1-FSTC installed
Operating Humidity
45% to 85% RH (no condensation)
Insulation Resistance
100MΩ minimum (500V DC megger)
Impulse Withstand Voltage
2.5kV
Pollution Degree
3
Output Configuration
See Installation and Maintenance on page 3
Overvoltage Category
II
Contact Material/Bounce
2
Gold plated silver / 20 ms
Electrical Life
100,000 operations minimum, 250,000 operations
minimum at 24V AC/DC, 100mA
Mechanical Life
250,000 operations
Shock Resistance
Operating extremes: 150 m/s
2
(15G)
Vibration Resistance
Operating extremes: 10 to 500Hz, amplitude 0.35
mm acceleration 50 m/s
2
LED Color
Red (The LED is built into the contact block and cannot
be replaced)
LED Voltage/Maximum Current
24V ac/dc ±10%, 15 mA
Total Weight of Padlock and Hasp (SSA-EB1M..-.. only)
1500g (3.3 lb) max.
Electrical Rating
Minimum load: 1 mA at 5V ac/dc
Maximum Rated Load: See table
UL Applications: 1.5A at 250V ac, 1A at 30V dc (pilot
duty)
CE Applications: AC-15: 1.5A at 250V ac, DC-13: 1A at
30V dc
Rated Insulation Voltage (Ui)
250V
Rated Current (Ith)
5A
B10d
100,000 (based on ISO13849-1(2006))
Terminals
M3 screw terminal (terminal cover included)
Recommended Torque: 0.6 to 1.0 N•m (5.3 to 8.8 in-lbf)
Allowable Wire: 0.75 to 1.25 mm
2
(18 to 16 AWG)
Design Standards
Compliant with EN/IEC 60497-1 / -5-1, ISO 13850, ANSI
B11.19 , ANSI NFPA79, IEC 60204-1
Date code format (U.S. Standard Format)
YYWWX: 2-digit year, 2-digit week, "X” internal code
Certifications
858T
Rated Operating Voltage (Ue) and Current
Safety Contact (N.C.) 30V 125V 250V
AC 50/60 Hz
Resistive Load (AC-12) - 5A 3A
Inductive Load (AC-15) - 3A 1.5A
DC
Resistive Load (DC-12) 2A 0.4A 0.2A
Inductive Load (DC-13) 1A 0.22A 0.1A
2
When the button is reset, the normally closed contacts will chatter. When pressing the button, the normally open contacts will chatter. When designing a control circuit, take
the contact chatter time into consideration. Do not expose the switch to external shocks, otherwise the contacts will bounce.
SSA-EB Series Emergency Stop Push Buttons
P/N 168349_web
Rev. B
www.bannerengineering.com - tel: 763-544-3164 7