Specifications

Monitor Contacts (N.O.) 30V 125V 250V
AC 50/60 Hz
Resistive Load (AC-12) - 1.2A 0.6A
Inductive Load (AC-14) - 0.6A 0.3A
DC
Resistive Load (DC-12) 2A 0.4A 0.2A
Inductive Load (DC-13) 1A 0.22A 0.1A
The operating current is classified according to JIS C 8201-5-1-1999 making and breaking capacities and are measured at
resistive/inductive load types specified in IEC 60947-5-1. See "Electrical Rating" above for specific model and UL/CE maxi-
mum ratings.
Checkout
At machine set up, a Designated Person
3
should test each emergency stop push button for proper machine shutdown response. A
Designated Person should check the emergency stop buttons for proper operation, physical damage, button looseness, and excessive
environmental contamination. This should take place on a periodic schedule determined by the user, based on the severity of the operat-
ing environment and the frequency of switch actuations. Adjust, repair, or replace components as needed. If inspection reveals contami-
nation on the switch, thoroughly clean the switch and eliminate the cause of the contamination. Replace the switch and/or appropriate
components when any parts or assemblies are damaged, broken, deformed, or badly worn; or if the electrical/mechanical specifications
(for the environment and operating conditions) have been exceeded. Always test the control system for proper functioning under
machine control conditions after performing maintenance, replacing the emergency stop device, or replacing any component of the de-
vice.
Dimensions
3
A Designated Person is identified in writing by the employer as being appropriately trained to perform a specified checkout procedure. A Qualified Person possesses a recognized degree
or certificate or has extensive knowledge, training, and experience to solve problems relating to the emergency stop installation.
SSA-EB Series Emergency Stop Push Buttons