Datasheet

Model Pushbutton EZ-Light
®
Illumination Logic and
Description
Connection
SSA-EB1PLXR-12ED1 Standard 40 mm OFF (armed), RED (flash, PUSH)
Terminal Strip, 1/2-
in NPT port
SSA-EB1PLYR-12ED1 Standard 40 mm YELLOW (armed), RED (flash, PUSH)
SSA-EB1PLGR-12ED1 Standard 40 mm GREEN (armed), RED (flash, PUSH)
SSA-EB1MLXRP-12ED1 Lockable 44 mm OFF (armed), RED (flash, PUSH)
SSA-EB1MLYRP-12ED1 Lockable 44 mm YELLOW (armed), RED (flash, PUSH)
SSA-EB1MLGRP-12ED1 Lockable 44 mm GREEN (armed), RED (flash, PUSH)
Important... Read this before proceeding!
The user is responsible for satisfying all local, state, and national laws, rules, codes, and regulations relating to
the use of this product and its application. Banner Engineering Corp. has made every effort to provide complete
application, installation, operation, and maintenance instructions. Please contact a Banner Applications Engineer with any
questions regarding this product.
The user is responsible for making sure that all machine operators, maintenance personnel, electricians, and
supervisors are thoroughly familiar with and understand all instructions regarding the installation, maintenance, and use of
this product, and with the machinery it controls. The user and any personnel involved with the installation and use of this
product must be thoroughly familiar with all applicable standards, some of which are listed within the specifications.
Banner Engineering Corp. makes no claim regarding a specific recommendation of any organization, the accuracy or
effectiveness of any information provided, or the appropriateness of the provided information for a specific application.
WARNING: Not a Safeguarding Device
An Emergency Stop Device is not considered a safeguarding device because it requires an
overt action by an individual to stop machine motion or hazards.
A safeguarding device limits or eliminates an individual's exposure to a hazard without action by the
individual or others. Because an individual must actuate the device for it to function, these devices do
not fit the definition of a safeguarding device and cannot be substituted for required safeguarding. Refer
to the relevant standards to determine those requirements.
Emergency Stop Considerations
ANSI NFPA 79, ANSI B11.19, IEC/EN 60204-1, and ISO 13850 specify emergency stop requirements, including the
following:
Emergency-stop push buttons shall be located at each operator control station and at other operating stations
where emergency shutdown is required.
Stop and emergency-stop push buttons shall be continuously operable and readily accessible from all control and
operating stations where located. Do not mute or bypass E-stop buttons.
Actuators of emergency-stop devices shall be colored red. The background immediately around the device actuator
shall be colored yellow (where possible). The actuator of a push-button-operated device shall be of the palm or
mushroom-head type.
The emergency-stop actuator shall be a self-latching type.
WARNING: Emergency Stop Functions
Do not mute or bypass any Emergency Stop device. ANSI B11.19, ANSI NFPA79 and IEC/EN
60204-1 require that the Emergency Stop function remain active at all times.
SSA-EB Series Emergency Stop Push Buttons
2 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 165998 Rev. E