Product Manual

05/19/2016 BI514
ELECTRO-BOILER
TS Series
INSTALLATION & OPERATING INSTRUCTIONS
Model EB-(S or WX)-13
EB-(S or WX)-18
EB-(S or WX)-23
EB-(S or WX)-27
APPLICATION: This Electro-Boiler is factory equipped with WarmFlo smart controller.
WarmFlo automatically regulates outlet water temperature based on a desired
output temperature set point.
Primary application is any hydronic water heating system where reduced flow or
radiation can cause overheat conditions (example, zones). However, if it is a
mixture of large and small zones, the sudden capacity and flow changes may
cause some internal timing/over temp conditions. With the mixture of zones the
Electro Industries’ zone controller option is highly recommended.
This series is equipped for load management interrupt and can apply to standard
baseboard radiation (not recommended for EB-S Model), dual heat combinations,
under floor radiant, wood boiler supplement, etc.
Note: If this installation does not include dual heat standby boiler, the front panel
switch must always be in the “normal” position.
ACCESSORIES: Attached BL001 lists various accessory or option items which are not part of
basic Electro-Boiler. See Room Thermostat Placement section for additional
information on slab stat. See Zone Controller section for information on a zone
control update which stages elements based upon zone capacity.
Note: This product meets the requirements of the ASME Boiler and Pressure Vessel Code.