WarmFlo Electric Plenum Duct Heater Technical Data Manual

SLC Series
This unit is specifi cally designed to be used in conjunction with Bryant Evolution
or Carrier
Infi nity
heat pump communicating thermostat systems. This unit allows for easy interface to
either the Evolution or the Infi nity system. This unit does not apply to Evolution or Infi nity air
conditioning systems, for air conditioning use WarmFlo Select SL1 Series. Note: The 286A or
288A outdoor unit and the “–B” thermostat control must be used in this application.
Features
Specifi cally designed for Evolution
or Infi nity
All-inclusive controls, for use with heat pump
Modulates electric elements to maintain precise output temperature
Quiet operation with individual DC relays
Energy control selector
Support Documents
Literature sheet - EL703
Installation manual - EI711
Wiring diagram - EH711
EZ-Mate Series
This unit can be used in conjunction with a single stage heat pump, with one or two-stage air
conditioning, or without air conditioning. This unit is compatible with single or multi-stage gas
or oil furnaces with or without variable speed blowers. This unit includes automatic dual fuel
control, with manual override switch. A conventional 4-wire thermostat must be used when
installing with a heat pump.
Features
Load shed
Application selection dial - HP or non-HP
All-inclusive controls, can be used with either heat pump or air conditioning
Stages electric elements to maintain precise output temperature
Quiet operation with individual DC relays
Energy control selector
Support Documents
Literature sheet - EL830
Installation manual - EI820
Wiring diagrams - EH808, EH810, EH811
WarmFlo
®
Select SLC Series - Wiring & Specifications
EZ-Mate
Series - Wiring & Specifications
Upfl ow Downfl ow
kW @
240VAC
Btu/h Amps
Circuit
Breakers
EM-WU102D
-SLC EM-WD102D
-SLC
10 34,000 21-21 60
EM-WU153D
-SLC EM-WD153D
-SLC
15 51,000 21-21-21 60-30
EM-WU204D
-SLC EM-WD204D
-SLC
20 68,000 21-21-21-21 60-60
EM-WU254D
-SLC EM-WD254D
-SLC
25 85,000 21-21-32-32 60-60-30
5 = 15” Wide 8 = 18” Wide
Upfl ow Downfl ow
kW @
240VAC
Btu/h Amps
Circuit
Breakers
Load Shed
CT
EM-LV104L
EM-LD104L
10 34,000 21-21 60 Yes
EM-LV104Z
EM-LD104Z
10 34,000 21-21 60 No
5 = 15” Wide 8 = 18” Wide
!24