CLEARANCES
MINIMUM CLEARANCE
SUGGESTED MINIMUM
SERVICE CLEARANCE
LEFT SIDE 1 INCH 26 MM 12 INCHES 305 MM
RIGHT SIDE 1 INCH 26 MM 12 INCHES 305 MM
BACK REQUIRED CLEARANCE – 0 INCHES/0 MM
FRONT REQUIRED CLEARANCE – 6 INCHES/153 MM
TOP REQUIRED CLEARANCE – 14 INCHES/356 MM
BOTTOM REQUIRED CLEARANCE – 14 INCHES/356 MM
SURROUNDING AMBIENT TEMPERATURE MUST NOT EXCEED 90° F/32° C.
CAUTION
For all installations, whether in a room or enclosed space, adequate ventilation must be
provided so this boiler’s surrounding ambient temperature does not exceed 90° F/32° C.
WARNING
FOR SAFETY REASONS ALL COMBUSTIBLE AND NON-COMBUSTIBLE MATERIALS MUST
BE KEPT AT LEAST ONE INCH AWAY FROM ANY SURFACE OF THIS BOILER.
CAUTION
This electric boiler is ONLY designed for indoor installation. It is NOT designed for outdoor
installation.