Electrical Installation 
 WARNING 
TO AVOID THE RISK OF ELECTRIC SHOCK OR DEATH, WIRING TO THE UNIT MUST BE 
PROPERLY GROUNDED. FAILURE TO PROPERLY GROUND THE UNIT CAN RESULT IN A 
HAZARD LEADING TO PERSONAL INJURY OR DEATH. 
Line Voltage 
The nameplate and/or Installation and Operating Manual specification page provides kW rating and 
operating current requirements for each specific model. Select the proper wire size to comply with your 
type of wire routing and NEC field wiring requirements. 
Field connection is at this product’s furnished circuit breaker. This integrated circuit breaker is a proper 
local disconnect. 
 WARNING 
USE ONLY COPPER WIRE FOR CONNECTION TO THE CIRCUIT BREAKER TERMINALS AND 
INSIDE THIS PRODUCT’S CABINET. 
If the 240 power service is to be wired as single feed, order option circuit breaker single feed bus bar, part 
number 5701. 
 WARNING 
DISCONNECT ALL ELECTRICAL POWER BEFORE ELECTRICALLY CONNECTING OR 
SERVICING THE UNIT. FAILURE TO DISCONNECT THE ELECTRICAL POWER BEFORE 
WORKING ON THIS PRODUCT CAN CREATE A HAZARD LEADING TO PERSONAL INJURY 
OR DEATH. 
Electric Furnace Control – Inside View, Right Board 
Room Thermostat, Air Conditioning 
Use conventional heat/cool, 1H/1C, thermostat. It can be mechanical, digital, power robbing, battery 
operated, setback, etc. If mechanical, set the heat anticipator to 0.2. 
Connect the standard R, W, G, Y stat terminals to the control board HEAT/COOL terminal block with 
the same letters. 
Room Thermostat, 2-Speed Air Conditioning 
Use conventional heat/cool, 2H/2C, thermostat. It can be mechanical, digital, power robbing, battery 
operated, setback, etc. If mechanical, set the heat anticipator to 0.2. 
Connect the R, W, G stat terminals to the control board HEAT/COOL terminal block with the same 
letters. 
Connect the Y1 stat terminal to the control board Y1 tab. Connect the Y2 stat terminal to the control 
board Y/Y2 screw terminal. 
The room thermostat W2 is not used or connected. 
Outdoor Unit, Air Conditioning 
Connect the outdoor unit 2 wires to the control board Y/Y2 and C. If 2-speed A/C, there will be a third 
wire connected to the tab Y1. 