Datasheet
Electrical
safety
1000 V CAT II / 1000 V CAT III / 600 V CAT IV, reinforced insulation, 36 amperes (at
+40
°C). According to EN / IEC 61010-031:2015.
These specifications come from the creepage distances, clearances, accessible parts, and
solid insulation of the clip. And the considered specifications of the environment are :
•
pollution degree, 1 or 2 ;
•
relative humidity, 80 % maximum for temperatures up to 31 °C decreasing linearly to
50 % relative humidity at +40 °C ;
•
temperature range, +5 °C to +40 °C ;
•
indoor use ; and
•
altitude, 2000 m maximum.
According to EN / IEC 60529. IP2X (
touchproof) when the jaws are closed.
Operating temperature range
-
20 °C mini., +80 °C maxi. (please see above too).
Conformity
•
European Directive "Low Voltage Directive" 2014/35/UE.
•
International / European standard EN / IEC 61010-031:2015.
•
European Directive “RoHS” 2011/65/EU. European Directive 2015/863/EU.
•
European regulation n°1907 / 2006 “REACH”.
•
European regulation 2017 / 821 “Conflict minerals”.
Environment
•
“RoHS” compliant, Pb ≤ 4 %, Hg ≤ 0.1 %, Cr VI ≤ 0.1 %, Cd ≤ 0.01 %, PBB ≤ 0.1
%,
PBDE ≤ 0.1 %, DEHP ≤ 0.1 %, BBP ≤ 0.1 %, DBP ≤ 0.1 %, and DIBP ≤ 0.1 %.
• “REACH” compliant, no substances from the candidate list of SVHC for authorization
at mass concentrations greater than 0.1 %.
Materials
Conductors : nickel
-coated steel, tinned steel, and brass. Insulators : please contact us.
Colors
Weight
0.020
kg.
Origin
Designed and manufactured in France.
Reliability benchmark
Year of 1st placing on the market
2005.
Dimensions in millimeters.
DATA SHEET (page 2 of 2).
Electro-PJP
France
www.electro-pjp.com
GLOSSARY :
ACCESSIBLE. Able to be touched with a standard test finger or test pin.
BASIC INSULATION. Insulation of HAZARDOUS LIVE parts which
provides basic protection.
CAT II. Measurement or overvoltage category II. For measurement
performed on / equipment connected to the building wiring.
CAT III. Measurement or overvoltage category III. For measurement
performed on / equipment connected to part of a building wiring installation.
CAT IV. Measurement or overvoltage category IV. For measurement
performed on / equipment connected to the origin of the electrical supply to a
building.
CLEARANCE. Shortest distance in air between two conductive parts.
CREEPAGE DISTANCE. Shortest distance along the surface of a solid
insulating material between two conductive parts.
CTI. Comparative Tracking Index of the insulating material in accordance
with IEC 60112.
DOUBLE INSULATION. Insulation comprising both BASIC INSULATION
and SUPPLEMENTARY INSULATION.
EN / IEC 60529. European / international standard regarding the degrees of
protection provided by enclosures.
EN / IEC 61010-1. European / international standard regarding the safety
requirements for electrical equipment for measurement, control, and
laboratory use – Part 1: General requirements.
EN / IEC 61010-031. European / international standard regarding the safety
requirements for electrical equipment for measurement, control and
laboratory use – Part 031: Safety requirements for hand-held probe
assemblies for electrical measurement and test.
"LVD". European Directive 2014/35/EU on the harmonization of the laws of
Member States relating to electrical equipment designed for use within
certain voltage limits. (Usually called the Low Voltage Directive.)
MAINS. Low-voltage electricity supply system to which the equipment
concerned is designed to be connected for the purpose of powering the
equipment.
MAINS CIRCUIT. Circuit which is intended to be directly connected to the
MAINS for the purpose of powering the equipment.
OVERVOLTAGE CATEGORY. Numeral defining a TRANSIENT
OVERVOLTAGE condition.
POLLUTION. Addition of foreign matter, solid, liquid or gaseous (ionized
gases), that may produce a reduction of dielectric strength or surface
resistivity.
POLLUTION DEGREE. Numeral indicating the level of POLLUTION that
may be present in the environment.
POLLUTION DEGREE 1. No POLLUTION or only dry, non-conductive
POLLUTION occurs, which has no influence.
POLLUTION DEGREE 2. Only non-conductive POLLUTION occurs except
that occasionally a temporary conductivity caused by condensation is
expected.
REINFORCED INSULATION. Insulation which provides protection against
electric shock not less than that provided by DOUBLE INSULATION.
"RoHS". European Directive 2011/65/EU on the restriction of the use of
certain hazardous substances in electrical and electronic equipment.
SOLID INSULATION. Insulating materials.
SUPPLEMENTARY INSULATION. Independent insulation applied in
addition to BASIC INSULATION in order to provide protection
against electric shock in the event of a failure of BASIC INSULATION.
TRANSIENT OVERVOLTAGE. Short duration overvoltage of a few
milliseconds or less, oscillatory or non-oscillatory, usually highly damped.
WORKING VOLTAGE. Highest r.m.s. value of the a.c. or d.c. voltage
across any particular insulation which can occur when the equipment is
supplied at rated voltage.
1000 V CAT II
1000 V CAT III
600 V CAT IV
Contact us at :
sales@electro-pjp.com
+33(0) 384 821 330
www.electro-pjp.com
ELECTRO-PJP
ZI «Charmes d’Amont»
13 rue de Madrid
39500 TAVAUX
FRANCE
Designation : Alligator Clip w/ 4 mm Banana (female) Jack (socket).
5066-IEC
Fingerguard. Keep behind this
fingerguard to operate safely
the clip while connecting to
hazardous live voltages (more
than 30 V AC and 60 V DC).
YellowBlack Red Green Blue White G/Y
GrayBrown Purple
The clip is constructed to
reduce the risk of short-
circuits and arc flashes.
For this purpose the metal
jaws can not be touched
when closed (IP2X).
Fichier «Datasheet_5066-IEC». 10/09/2019. Indice D. Information in this publication supersedes all earlier versions. Specifications subject to change without notice. © 2019 Electro-PJP.