Owner's Manual

20 en | Technical data EVID Ceiling Speaker Systems
2018.09 | 11 | F.01U.177.705 Installation manual Electro-Voice
6 Technical data
EVID C4.2 and EVID-C4.2LP
Specification EVID C4.2 C4.2LP
Frequency response 65 Hz - 20 kHz 60 Hz - 20 kHz
Sensitivity (SPL 1 W/1 m) 86 dB
Coverage pattern 130° conical
Power handling (@ 8Ω) 50 W (with overload protection)
Rated Impedance 8 Ω
Recommended High-Pass
frequency:
65 Hz
Input configuration 8Ω; 70V/100V
70V/100V power taps 1.8 (70V only)/3.7/7.5/15/30 W
LF transducer 4 in (100 mm) high-compliance
driver (weatherized cone)
4 in (100 mm) high-compliance
driver (weatherized cone)
HF transducer 0.75 in (19 mm) Ti-coated dome 0.75 in (19 mm) Ti-coated dome
Mounting system Integrated 3-point toggle anchors Integrated 4-point toggle anchors
Acoustic design Ported cabinet, two-way design, internally damped, w/passive
crossover
Cabinet construction Steel enclosure and UL94V-0 rated baffle and bezel
Grille construction Powder-coated steel
Color White (paintable)
Cutout dimensions (diam.) 7.1 in (180 mm) 10.6 in (269 mm)
Dimensions (depth x diam.) 6.9 in x 8.3 in (176 mm x 211 mm) 3.7 in x 11.8 in (94 mm x 300 mm)
Net weight 6 lb (2.7 kg) 7.35 lb (3.32 kg)
Included accessories Tile bridge, mounting ring
Safety agency ratings UL 1480
Safe for use in air handling spaces per UL 2043
EVID-C6.2 and EVID C8.2
Specification EVID-C6.2 EVID C8.2
Frequency response 50 Hz - 20 kHz 50 Hz - 20 kHz
Sensitivity (SPL 1 W/1 m) 90 dB 91 dB
Coverage pattern 120° conical 110° conical
Power handling (@ 8Ω) 75 W (with overload protection)
Rated Impedance 8 Ω