Manual

Technical specifications AW 600:
The following technical data were measured on randomized test objects and are typical
data.
All measurements are made at 120V / 240V // 50Hz / 60Hz
Clipping point of the amplifier is set to a level where total harmonic distortion (THD) is 0.2 %.
Measurements Parameters Balanced
Input impedance (Fixed) 55 kohm
Input level for rated output (RMS) 1 V
Frequency response (DC - 65 kHz) -0.4 dB
Noise* (400 - 30 kHz) < 150 µV
(DC – 30 kHz) < 200 µV
Output Impedance (20 Hz - 20 kHz) < 0,009 ohm
Damping factor (20 Hz – 20 kHz) > 900 X
Maximum peak current > 150 A
THD (1 kHz, half power, 8ohm) < 0,001 %
THD (1 kHz, -1 dB, 8 ohm) < 0,0015 %
* Noise is measured with input shorted.
Rated output power
10 % change in line voltage will give approximately 20 % change in output power.
8 ohm - 600 W
4 ohm - 1200 W
Power consumption 230 W no load or signal
The AW 600 is DC coupled from input to output.
Dimensions
Width: 514 mm - 20.2 “
Depth: 470 mm - 18.5 ”
Height: 288 mm - 11.3 ”
Weight: 41 kg - 90.2 lbs.
Specifications subject to change without notice.
GBUSA
4
nemo.pdf 5 10/28/2009 8:11:38 AM