Installation Instruction

Technical features
Gas burners power
Ultra-rapid treble crown burner (big) 4,0 Kw
Rapid burner (big) 3,0 Kw
Auxiliary burner (small) 1,0 kW
Semi-rapid burner (medium) 2,0 kW
Category II2H3+
Appliance Calibration Methane Gas 20 mbar
Gas inlet connector G 1/2"
Feeling tension 230 V 50 Hz
Dimensions for the recess
opening
Width 264 mm
Depth 531 mm
Instructions for the installer
WARNING: This appliance can be installed and can
work only in permanently well-ventilated rooms in
accordance with o UNI 7129 e UNI 7131 regulations.
The installation of the appliance and the connection to
the electric network must be carried out exclusively by
QUALIFIED PERSONNEL ONLY. Before doing any
sort intervention it is important to verify the equipment is
disconnected from the electrical network
Room of installation
In order to have a proper working of the gas appliance it
is of main importance to grant a natural air circulation in
the room, the air necessary for the gas combustion. (the
installer must strictly follow the current directives UNI-
CIG 7129 - 7131).
The air circulation must be ensured through openings in
walls to the outside (as indicated in picture 7).
These openings must have a free passing section of at
least 100 cm 2.
This opening must be made in such a way that cannot
be obstructed from the outside, near the floor level and
positioned on the opposite side of the exhaust system.
7
If this opening cannot be made in the room where the
appliance is installed, the necessary air can come from a
near room, but:
this room cannot be a bedroom;
this room cannot be in depression;
the ventilation between the room where the appliance is
installed and the near room has to be insured by
permanent openings. (UNI-CIG 7129).
mediante aperture permanenti (UNI-CIG 7129).
FROM ANY RESPONSABILITY IN CASE OF
DEMAGES CAUSED BY AN INSTALLATION NOT
IN COMPLIANCE WITH THE CURRENT
REGULATIONS AND WITHOUT RESPECTING
THE ACCIDENT PREVENTION RULES.
.