Operating instructions

4
Installation Requirements
NOTE
GFI (Ground Fault Interrupter) receptacle is not required.
NOTE
Because of potentially inconsistent voltage capabilities,
the use of this washer with power created by gas powered
generators, solar powered generators, wind powered
generators or any other generator other than the local utility
company is not recommended.
CIRCUIT - Individual, properly polarized and grounded 15
amp. branch circuit fused with 15 amp. time delay fuse or
circuit breaker.
POWER SUPPLY - 2 wire, with ground, 120 volt single phase,
60 Hz, Alternating Current.
OUTLET RECEPTACLE - Properly grounded 3-prong
receptacle to be located so the power supply cord is
accessible when the washer is in an installed position.
Grounding type
Grounding type
wa
wa
ll receptacl
ll receptacle
Po
Po
wer cord with
wer cord with
3-prong
3-prong
gr
gr
ounded plug
ounded plug
Do not,
Do not,
under
under
an
an
y cir
y cir
cumstances,
cumstances,
cut,
cut,
remo
remo
ve
ve,
or b
or b
ypass th
ypass the
gr
gr
ounding pr
ounding pr
ong.
ong.
56.5”
(144cm)
max.
24”
(61cm)
min.
Drain system requirements
1 Drain capable of eliminating 6 gals (22.5 L) per minute.
2 A standpipe diameter of 1-1/4 in. (3.18 cm) minimum.
3 The standpipe height above the floor should be:
Minimum height: 24 in. (61 cm)
Maximum height: 56.5 in. (144 cm)
Water supply requirements
Hot and cold water faucets MUST be installed within hose
length of your washer’s water inlet. The faucets MUST be 3/4
inch (1.9 cm) with threading for laundry hose connection.
Water pressure MUST be between 10 and 110 psi. Pressure
difference between hot and cold cannot be more than 10
psi. Your water department can advise you of your water
pressure.
1 The washer MUST be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electrical shock by a path of least resistance for
electrical current.
2 Since your washer is equipped with a power supply
cord having an equipment-grounding conductor and
a grounding plug, the plug MUST be plugged into an
appropriate, copper wired receptacle that is properly
installed and grounded in accordance with all local
codes and ordinances or in the absence of local codes,
with the National Electrical Codes, ANSI/NFPA 70
(latest edition). If in doubt, call a licensed electrician.
DO NOT cut off or alter the grounding prong on the
power supply cord. In situations where a two-slot
receptacle is present, it is the owner’s responsibility to
have a licensed electrician replace it with a properly
grounded three prong grounding type receptacle.
Ground requirements
Electrical system requirements
MINIMUM INSTALLATION CLEARANCES - Inches (cm)
SIDES REAR TOP FRONT
Alcove 0” (0 cm) 0” (0 cm)* 0” (0 cm) n/a
Under Counter 0” (0 cm) 0” (0 cm)* 0” (0 cm) n/a
0”
(0cm)
0”
(0cm)
0”
(0cm)
Clearance requirements
WARNING
ELECTRICAL SHOCK HAZARD
Improper connection of the equipment grounding conductor
can result in a risk of electrical shock. Check with a
licensed electrician if you are in doubt as to whether the
appliance is properly grounded.