Exhaust system requirements
Use only 4 inch (102 mm) diameter rigid or exible
metal duct and approved vent hood which has a swing-
out damper(s) that open when the dryer is in operation.
When the dryer stops, the dampers automatically close
to prevent drafts and the entrance of insects and rodents.
To avoid restricting the outlet, maintain a minimum of 12
inches (30.5 cm) clearance between the vent hood and the
ground or any other obstruction.
Correct Incorrect
Correct Incorrect
If your present system is made up of plastic duct or metal
foil duct, replace it with a rigid or semi-rigid metal duct.
Also, ensure the present duct is free of any lint prior to
installing dryer duct.
The following are speci c requirements for
proper and safe operation of your dryer.
WARNING
FIRE HAZARD
Failure to follow these instructions can create excessive
drying times and re hazards.
WARNING
FIRE HAZARD
Do not install a clothes dryer with exible plastic or
metal foil venting materials. Flexible venting materials
are known to collapse, be easily crushed and trap lint.
These conditions will obstruct clothes dryer air ow and
increase the risk of re.