User manual

Frost precautions
If the appliance is installed in an area
where the temperature can reach the
values around 0° C or drop below, remove
the remaining water from the inlet hose
and the drain pump.
1. Disconnect the mains plug from the
mains socket.
2. Close the water tap.
3. Put the two ends of the inlet hose in a
container and let the water flow out of
the hose.
4. Empty the drain pump. Refer to the
emergency drain procedure.
5. When the drain pump is empty, install
the inlet hose again.
WARNING! Make sure that the
temperature is higher than 0 °C
before you use the appliance
again.
The manufacturer is not
responsible for damages
caused by low temperatures.
TROUBLESHOOTING
WARNING! Refer to Safety
chapters.
Introduction
The appliance does not start or it stops
during operation.
First try to find a solution to the problem
(refer to the table). If the problem persists,
contact the Authorised Service Centre.
In case of major problems, the acoustic
signals operate, the display shows an
alarm code and the Start/Pause button
may flash continuously:
- The appliance does not fill with
water properly.
Start the appliance again by pressing
Start/Pause button. After 5 seconds the
door will be unlocked.
- The appliance does not drain
the water.
- The appliance door is open or
not closed correctly. Please check the
door!
If the appliance is
overloaded, remove some
items from the drum and/or
keep pressed the door while
touching the Start/Pause
button until the indicator
stops flashing (see the
picture below).
- The mains supply is unstable.
Wait until the mains supply is stable.
- No communication between
electronic elements of the appliance.
Switch it off and switch on again.
The programme was not finished
properly or the appliance stopped too
early. If the alarm code appears again,
contact the Authorised Service Centre.
- The anti-flood device is on.
Disconnect the appliance and close the
water tap. Contact the Authorised
Service Centre.
WARNING! Deactivate the
appliance before carrying out
any check.
28