OPERATING AND INSTALLATION INSTRUCTIONS FOR ELECTROLUX REFRIGERATORS INTRODUCTION CONTENTS We are pleased that you have chosen this refrigerator and hope you will derive much satisfaction from using it, but first a few well-meant words of advice: OPERATING INSTRUCTIONS It is important to read through these instructions carefully before using the refrigerator. To ensure good refrigeration and economical operation , the refrigerator must be installed and used as described in these instructions.
OPERATING INSTR UCTIONS 8. Keep the (0) button pressed for a further 10 to 15 secon ds to active the flame failure device, then release it. CONTROLS If you have Model RM 4270 proceed as follows: 3. Turn on the gas supply by pressing the (0) knob and turning it to the position The refrigerator can be run on either 230 V, 12 V or LP gas. Changing between these modes of operation is carried out by means of the controls of the control panel shown in fig 3. 4.
CLEANING THE REFRIGERATOR TRAVEL CATCH Make sure that the travel catch is engaged when the cara van is on the move, (fig 1). Clean the inside of the refrigerator regularly to keep it fresh and hygienic. The travel catch at the top of the door can be set in two different positions. In one position the door is held tightly shut. In the other position the door is secured ajar so that the refrigerator can be aired when not in use.
2. The evaporator is frosted up. TECHNICAL DATA 3. The temperature control setting is incorrect. 4. The gas pressure is incorrect lator at the gas container. RM 4270/71 Overall dimensions, refrigerator Height ............ Width ................... Depth (inc!. cooling unit) without door with door check the pressure regu 5. The ambient temperature is too high. 6. To much food is loaded at one time. 7 . The door is not properly closed or the magnetic sealing strip is defective.
• Remove the lower trim moulding and then withdraw the panel by sliding it downwards. • Fit new panel in place and slide it up as far as possible. • Fit the trim moulding back in place. Locate the lower opening immediately above the floor of the recess, and the upper one as high as possible above the condenser (C) of the refrigeration unit, at least as shown in fig. 6b but preferably as shown in fig. 6a. Ventilation grilles Fig.
Check that this is stated on the data plate. The refrigerator is not designed for operation on town gas or natural gas. 3 amp. fuse. In other countries, the fuse rating will depend upon the voltage and local practice . The gas installation should only be carried out by an authorized gas fitter. 230 V Supplies. The supply pipe should preferably be of copper.