MANUAL CARAVAN AES II RM 4185 RM 4215 RM 4235 RM 4265 RM 4275 RM 4285 RM 4365 RM 4405 RM 5215 RM 5275 RM 5405 Deutsch Seite 1 Svenska sida 32 English page 7 Dansk side 38 Français page 14 Norsk side 44 Italiano pagina 20 Nederlands pag. 50 Español pagina 26 Suomi sivu 57 C 40/ 110 821 2647.12 T.B.
OPERATING AND INSTALLATION INSTRUCTIONS FOR ELECTROLUX REFRIGERATORS INTRODUCTION CONTENTS We are pleased that you have chosen this refrigerator and hope you will derive much satisfaction from using it, but first a few well-meant words of advice: OPERATING INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . 8 CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 It is important to read through these instructions carefully before using the refrigerator.
Then push button (A) to "ON" again. After 10 sec. AES will repeat the ignition sequence. When the AES LED (C) again starts flashing red after 30 sec, the trouble persists (air in the line, no gas?). Switch (A) briefly off and then on again. It might be necessary to repeat this operation 3-4 times if the tubing contains air (after changing gas bottles, repairs etc). If this does not help, you should consult a service technician.
for all three sources of energy, by means of the thermostat knob (B). After turning on the refrigeratior the system automatically chooses the mid- position. With some experience you will soon find a suitable setting. This normally does not need resetting because the same thermostat controls the main compartment temperature for any of the three sources of energy. receptacle at the rear of the refrigerator where it evaporates. Defrost water in the freezer compartment should be mopped up with a cloth.
. The ambient temperature is too high. 6. To much food is loaded at one time. 7. The door is not properly closed or the magnetic sealing strip is defective. The refrigerator must not be exposed to radiated heat from hot objects (e.g. below a cooker without proper heat shielding). Excessive heat irradiation impairs performance and leads to increased energy consumption.
The gas installation should only be carried out by an authorized gas fitter. It is recommended that the gas pipe feeding the refrigerator is so arranged that it is possible to turn off the supply of the refrigerator. It must be of a type approved for use with continuously operating bottled-gas appliances, and have threaded compression connections throughout.
WARNING! THIS APPLIANCE MUST BE EARTHED. Cross- sections In the United Kingdom, the plug or circuit to the refrigerator must be fitted with a fuse not greater than 5 amps. If a 13 amp.(B.S.1363) fused plug is used, it should be fitted with a 3 amp. fuse. In other countries, the fuse rating will depend upon the voltage and local practice. The D+ (alternator) connection does not carry high current, therefore it is no need to use a high cross- section cable.
TECHNICAL DATA RM RM Overall dimensions, refrigerator Height (incl.controls) Width Depth (incl.cooling unit) without door with door Recess dimensions Height Width Depth Step (wheel house) Height Width Depth Capacity gross net frozen food compt. Weight (without packaging) Electrical data Input 230 V 12 V **Energy consumption (in 24h) LP gas data Input, max.