When a failure occurs in the ESEC system the control will beep and half
of the power level indicator segments for the surface elements will ash in
various combinations to indicate which error has occurred. (Fig. 1)
The troubleshooting guide provides a listing of the likely failure condition or
cause, as well as suggested corrective actions to be taken.
Perform the steps one at a time in the order listed below to correct the
specic failure condition. In some cases you can also use the diagnostic
service mode described on page 17 to determine which ESEC error
condition is present
ERROR CODES - IQ Touch Models
SYMPTOM LIKELY FAILURE CONDITION/
CAUSE
SUGGESTED CORRECTIVE ACTION
Control Beeping &
Center Burner Only
LED’s Flashing
ESEC key display ribbon cable is
disconnected or defective
1. Check/reseat ribbon connection J3 connection on the ESEC 30 UIB.
2. Replace ESEC 30 UIB.
3. Replace TST panel.
Control Beeping &
Left Side Burners
Only LED’s
Flashing
ESEC key display ribbon cable is
disconnected or defective
1. Check/reseat ribbon connection J2 connection on the ESEC30 UIB.
2. Replace ESEC 30 UIB.
3. Replace TST panel.
Control Beeping &
All Burners LED’s
Flashing
E11 Failure Mode - Shorted Keypad
or
E14 Failure Mode - ESEC key
read ribbon cable is unplugged or
defective
or
E15 Failure Mode - Internal ESEC
error or Signal loss between ESEC
30 UIB and ESEC relay board.
Turn off power to range for 30 seconds then reapply power.
Does error return within 5 seconds ?
YES: Go to Solution A
NO: Does error return after 30 seconds?
YES: Go to Solution B NO: Test operation. If error does not return then the
condition was corrected by power reset.
Solution A - E14 Failure Mode key read ribbon cable is disconnected or defective
1. Check/reseat ribbon connection J4 connection on the ESEC 30 UIB.
2. Replace ESEC 30 UIB.
3. Replace TST panel.
E15 Failure Mode ESEC error or signal loss between ESEC 30 UIB and relay board.
1. Check harness and connections between connector P6 of ESEC30 UIB to
connector J2 of ESEC relay board. Repair or replace harness as needed.
2.. If connection and harness are good, then replace ESEC relay board.
3. If error remains replace ESEC30 UIB.
4. If the previous steps do not resolve the failure replace the TST panel.
Solution B - E11 Failure Mode Shorted Keypad
1. Reset power supply to range to see if failure code will clear.
2. Check/reseat ribbon harness and connectors between the TST panel and ESEC
30 UIB.
3. Replace the TST panel
4. Replace the ESEC 30 UIB
Fig 1
ELECTRONIC SURFACE ELEMENT CONTROL (ESEC 30) TROUBLESHOOTING GUIDE
- IQ Touch Models-