INSTALLING THE COOKER HOOD
Ducting Connection
Connect the ducting chosen to:
the Ø150mm ducting spigot on top of the motor
housing, or the Ø150-120mm ducting spigot item 9
and secure using the jubilee clips item 25.
A Ø120-125mm collar item 9.1 is provided to t over
the Ø120mm ducting spigot when 125mm ducting is
tted.
If the room where the cooker hood is to be used
contains a fuel burning appliance such as a central
heating boiler, then its ue must be of the room
sealed or balanced ue type.
If other types of ue or appliances are tted sure
that there is an adequate supply of air to the
room.
The cooker ducting (extraction mode) must never
be connected to central heating ues, radiators or
water heaters etc.
Recirculation
The cooker hood is supplied speci ed for use in the
recirculation mode, with the charcoal lter tted.
In the recirculation mode contaminated air is passed
through the charcoal lter to be puri ed and recirculated
into the kitchen through the grille outlets on either side
of the chimney.
Recirculation Connection
Fix the connection item 15 to the frame using the 4
screws provided.
• Fix the ange item 10 to the lower opening of the
connection item 15.
Connect the hood air outlet to the ange in the lower
part of the junction using a rigid or exible ø 150
tube (by installers choice).
9
ø 150
ø 125
25
25
9.1
15
10