User manual

9
PROGRAMMING
Temperature warning
The unit will automatically report if the temperature will exceed the set value. The default setting for low temperature alarm is +5°C and for high
temperature 30°. These values can be changed to between 0°C and +50°C. To change a set value, send the following text message to the unit:
Request current temperature
To see what the current temperature is where your ControlBox24/7 is located, send the following text message to the unit:
TEMP
LOW TEMPERATURE ALARM
LTWARN <NUMBER> Example: LTWARN 12
The example above will cause the unit to send a warning report when the
temperature falls below 12°C, as
“Temperature - LOW”.
If the temperature then increases again and reaches the set value,
another message will be sent saying:
“Temperature - RESTORED”
The unit’s temperature warning function can be easily activated or
deactivated using the following command:
Activation: LTWON (default setting)
Deactivation: LTWOFF
HIGH TEMPERATURE ALARM
HTWARN <NUMBER> Example: HTWARN 27
The example above will cause the unit to send a warning report when the
temperature exceeds 27°C as
“Temperature - HIGH”.
If the temperature then decreases again and reaches the set value,
another message will be sent saying:
“Temperature - RESTORED”
The unit’s temperate warning function can be easily activated or
deactivated using the following command:
Activation: HTWON
Deactivation: HTWOFF (default setting)