Installation Guide
8
30" & 36" DUAL FUEL RANGE INSTALLATION INSTRUCTIONS
Recommended Wall Outlet Installation
Locations
Suggested location of the wall outlet is shown in Figure 4
for 30" models and in Figure 5 for 36" models. The
outlet may also be located in the lower left corner of the
adjacent right cabinet, as shown in Figure 6
Figure 4: 30" Models Outlet Location
Figure 5: 36" Models Outlet Location
12”
(30.5 cm)
8”
(20.3 cm)
Figure 6: Adjacent Cabinet Outlet Location
Figure 7: Factory connected power supply cord
3
Power Supply Cord
This appliance is equipped with a factory-connected,
4-wire power supply cord (Figure 7). This cord is rated
at 240 volts, 40 amps, and temperature rated at 194°F
(90°C). This cord is UL/CSA listed and has been tested
and approved for use with this appliance.
Appliance Rating* Power Supply
Rating
120/240 Volts 120/208 Volts Amps
1-10 kW 0-7.6 kW 30
8.8-16.5 kW 7.8-12.5 kW 40 or 50
16.6-22.5 kW 12.6-18.5 kW 50
* The NEC calculated load is less than the total connec-
ted load listed on the serial plate.
Electrical Shock Hazard –Do not attempt to install
the appliance directly to a junction box, modify the
factory-installed cord, or connect a different power
cord to the appliance. If the wall outlet is not sufcient
to support the requirements of this appliance, it is the
responsibility of the consumer to have the appropriate
outlet installed by an electrician. Improper installation
and electrical connections can result in electric shock,
damage to the appliance, personal injury, re, or death.
Locate Electrical Hook-up
Inside Shaded Area
Center
Line of
Range
14"
(35.6 cm)
FLOOR
WALL
Center
Line of
Range
5" Max.
(1 cm Max.)2.7
Locate Electrical Hook-up
Inside Shaded Area
Center
Line of
Range
7" Max.
(17.8 cm Max.)
10"
(25.4 cm)
FLOOR
WALL
Center
Line of
Range