Manual

Alarms & Sabbath Mode
L ........
Door Ajar Alarm
This alarm will sound to alert you that the door has been open for 5 minutes or more. The ............................
DOOR AJAR LED will illuminate and the audible alarm will sound until the door isclosed.
The audible alarm can be tumed off by pressing the ALARM OFF key or by closing the
door. If the door is ajar for 35 minutes, the interiorlight will turn off.
Temp Sensing Error Alarm
The sensor alarm signals you that a problem exists with a temperature sensor. The
audible alarm will sound after 1 hour and the display will alternate between "E8" or "E9"
and -10_'F (-23°C) at 1/_second intervals.The control will then enter a mode that runs the
appliance in a manner that maintains the factory set cabinet temperature.
The audible alarm can be turned off by pressing the ALARM OFF key.
Stuck Key Alarm ;;;;;;;;;;;;;;;;;;
The stuck key alarm will sound if the control reads a keypress for longer than 30 ;;;;;;;;;;;;;;;;
seconds. The audible alarm will sound and will be limited to 1minuteoand will stop
1
automatically. The display will alternate between "E7" and -10 F (-23 C) at b second
intervals. The control will then enter a mode that runs the unit in a manner that maintains .....
the factory set cabinet temperature until the condition is resolved.
The audible alarm can be turned off by pressing the ALARM OFF key.
Sabbath Mode
The Sabbath Mode is a feature that disables portions of the appliance and its controls in
accordance with the observance of the weekly Sabbath and religious holidays within the
Orthodox Jewish community.
To initiate or cancel Sabbath Mode, press the CONTROL LOCK and TEMP MODE keys
at the same time and hold for 3 seconds. The display will now show "Sb" and the confi
rmation tone will sound. When AC power is cycled while the control is in Sabbath mode,
the control enters into Sabbath mode automatically. "Sb" will again be displayed. While in
Sabbath Mode, the display will show "Sb" for one second if any key is pressed.
In the interest of food safety, only the HIGH TEMP Alarm remains active and takes
precedence over other Sabbath Mode features.
._For assistance, guidelines proper usage a complete
further for and list of models
with the Sabbath feature, please visit the web at http:\\www.star-k.org.
[ sb. ...................
I :.... ..................
/ ,_:,\