Service manual

Component Teardown
6-12
The compressor area components for the All Refrigerator
and All Freezer-Pro Units are similar in layout and have
the same access and removal steps. However, the part
numbers for items in the compressor area may differ
between the all refrigerator and all freezer models.
Power Cord Removal
The power cord enters the compressor area on the lower
left side and is secured to the compressor mounting plate
with a P-clamp and screw.
To remove the power cord:
1. Pull unit from its installation position to access the
rear compressor area. Disconnect power from unit.
2. Using a phillips head screwdriver, extract the four
screws securing the compressor area shield to the
rear of the unit. Remove shield.
3. Using a 1/4” socket or wrench, extract the screw
securing the P-clamp to the compressor mounting
plate. (See Figure 6-26)
4. Using a 1/4” socket or wrench, extract the screw
securing the ground wires to the compressor
mounting plate.
5. Disconnect power cord from the wire harness at the
quick disconnect. Remove power cord from unit.
Water Valve Removal (if equipped)
The water valve is secured with two screws to the
right hand side of the unit behind the compressor
area shield.
To remove the water valve:
1. Pull unit from its installation position to access the
rear compressor area.
2. Using a phillips head screwdriver, extract the four
screws securing the compressor area shield to the
rear of the unit. Remove shield.
3. Disconnect water valve from household water
supply. (See Figure 6-27)
4. Using fingers, disconnect the icemaker water line
from water valve.
5. Using a 1/4” socket or wrench, extract screws
securing water valve to unit frame.
6. Disconnect electrical connections from terminals of
water valve.
Figure 6-26. Power Cord Removal
Electrical
Connection
Ground
Screw
P-Clamp
and Screw
Figure 6-27. Power Cord Removal
Electrical
Connection
Screws
Household
Inlet
To Ice
Maker
Compressor Area Components
All Refrigerator and All Freezer-Pro Models