Service manual

Component Teardown
6-16
Condenser Coil Removal
The condenser coil is mounted to the drain pan by four
retaining clips.
To remove the drain pan:
1. Pull unit from its installation position to access the
rear compressor area. Disconnect power from unit.
2. Extract the screws securing the compressor shield to
the unit frame and remove from unit.
3. Recover refrigerant by using EPA approved recovery
system.
4. Remove condenser fan assembly from unit.
5. Disconnect inlet and outlet lines from condenser.
(See Figure 6-33)
6. The front of the unit will need to be raised to access
the drain pan screws.
7. Using a short phillips head screwdriver, extract the
four screws securing the drain pan to the bottom of
the unit frame.
8. Allow the drain pan to drop down. Pull drain tube
from drain pan.
9. Pull condenser tubes out of the retainers mounted to
the drain pan. Remove condenser from unit.
10. Replace old filter-drier after installing the new
condenser.
Cut Here
Figure 6-33. Condenser Coil Removal