Service manual

Component Teardown
Figure 6-42. Door Switch Removal
Door Switch
Access Hole
6-19
Door Gasket and Inner Panel Removal
The inner panel of the door assembly is secured with
screws that pass through the inner panel and fasten
into the door assembly. The door gasket has an inner
lip that is pressed between the inner panel and the door
assembly and is secured in position when the inner panel
screws are fastened to the door assembly. The inner
panel does not have to be completely removed to extract
the door gasket from the door assembly.
To remove the door gasket:
1. Lift the inside edge of the door gasket to access the
inner panel screws.
2. Loosen the inner panel screws until the door gasket
can be pulled out from under the inner panel.
(See Figure 6-41)
3. Continue loosening screws around door assembly
until door gasket is free.
4. To remove the inner panel, extract all screws from
the outside edge of the inner panel and remove from
unit.
5. The secondary gasket is secured with two retaining
clips that snap into the inner door panel. Pry out
the two retaining clips with a small putty knife, using
caution not to damage the inner door panel. The
secondary gasket is now free.
Door Switch Removal
The door switch is mounted inside a hole in the cabinet
base along the lower left hand side. (See Figure 6-42)
To remove the door switch:
1. Disconnect power from unit.
2. Remove kickplate.
3. Reach into the access hole next to the door switch
and disconnect the electrical leads from the door
switch terminals.
4. Press in on the retaining latch on the switch body
and push switch through hole in cabinet base.
Figure 6-41. Inner Panel and Door Gasket Removal
Screw
Inner Panel
Door
Gasket
Outer
Door
Panel
Secondary
Gasket
Clip