INSTRUCTIONS MANUAL SPLIT TYPE ROOM AIR CONDITIONER MODELS: EAS(C,E)09P5AHLWC EAS(C,E)12P5AHLWC EAS(C,E)18P5AHLWC EAS(C,E)24P5AHLWC 140224A S5(20-23)EM_ENGLISH R410a_CHILE Please read this manual completely before operating your room air conditioner.
contents electrolux 02 01 electrolux welcome Welcome to the world of simple handling and no worries. Contents Thank you for choosing Electrolux. This manual contains all of the information required to guarantee your safety and the appropriate use of your air conditioner. Welcome.........................................................................................................01 Please read all of the instructions before using the air conditioner and keep this manual for future reference.
03 electrolux contents safety precautions electrolux 04 Safety precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. The air conditioner that you have bought may be slightly different from the one illustrated in this manual. Please refer to the information related to the model you have. This air conditioner is for domestic use only. It is not reccomended for commercial or industrial use.
safety precautions electrolux 06 05 electrolux safety precautions conditioner. It contains contaminants and could make you sick. 10.Do not use the power cord close to heating appliances. It may cause fire and electric shock. 11.Do not damage or use an unspecified power cord. It may cause electric shock or fire. 12.Do not direct airflow at room occupants only. This could damage your health. 13.Always install circuit breaker and a dedicated power circuit. No installation may cause fire and electric shock.
choosing the installation site electrolux 08 07 electrolux safety precautions Choosing the installation site falling of unit. Precautions for Installation 28.Always insert the filters securely. Clean filter once every two weeks. Operation without filters may cause failure. Installation at the following sites may cause problems. If you must inevitably install the unit at one of these sites, please consult your local distributor beforehand: 29.
parts list electrolux 10 09 electrolux outdoor unit Parts list Outdoor Unit 1. The outdoor unit must be installed at a convenient site that is not exposed to strong winds. The site should be dry and well ventilated. More than 30cm More than 60cm More than 30cm 2. The site must support the weight of the outdoor unit and allow for vertical installation. 3. There must not be the possibility of increased noise and vibration at the site. 4.
indoor unit installation electrolux 12 11 electrolux parts list Indoor unit installation Installation plate description 1 More than 15cm 2 3 Indoor unit 45 41 More than 12cm 6 More than 12cm Air filter 2,3m or more 6 More than 60cm 7 A More than 60cm 45 4 41 More than 30cm 5 C More than 200cm Outdoor unit 45 B 1. This illustration is for explanation purposes only. 2.
indoor unit installation electrolux 14 13 electrolux indoor unit installation Connective pipe and drainage installation Drainage 1. Run the drain hose sloping downward. Do not install the drain hose as illustrated below. Do not block water flow by a rise. Do not block water flow by a rise. 2. When connecting extension drain hose, insulate the connecting part of extension drain hose with a shield pipe, do not let the drain hose slack. Do not put the end of drain hose into water.
outdoor unit installation electrolux 16 15 electrolux indoor unit installation Outdoor unit installation 3. Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall. Get it out after finish piping. 4. Push the lower part of the indoor unit up on the wall, then move the indoor unit from side to side, up and down to check if it is hooked securely. Piping and wrapping 1.
refrigerant pipe connection electrolux 18 17 electrolux outdoor unit installation Refrigerant pipe connection A Settlement of outdoor unit Anchor the outdoor unit with a bolt and nut 10 or 8 tightly and horizontally on a concrete or rigid mount.
electrical work electrolux 20 19 electrolux refrigerant pipe connection Electrical work Electric safety regulations for the initial Installation 4. Flaring work A) Firmly hold copper pipe in a die in the dimension shown in the table below. OUTER DIAMETER (mm) Copper pipe Handle A (mm) Máx. Mín. 6,35 1,3 0,7 9,52 1,6 1,0 12,70 1,8 1,0 16 2,2 2,0 Connection Adjustment 1. Align the pipes to be connected. 2.
electrical work electrolux 22 21 electrolux electrical work Connect the cable to the indoor unit Electric safety regulations for the initial Installation 1. If there is serious safety problem about the power supply, the technicians should refuse to install the air conditioner and explain to the client until the problem is solved. 2. Power voltage should be in the range of 90%~110%of rated voltage. 3. The surge protector and main power switch with a 1.5 times capacity of Max.
electrical work electrolux 24 23 electrolux electrical work Connect the cable to the outdoor unit Terminal block of outdoor unit 1. Remove the electrical control board cover from the outdoor unit by loosening the screw. 2. Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units. 3. Secure the cable onto the control board with the cord clamp. 4.
electrical work electrolux 26 25 electrolux electrical work Caution After the confirmation of the above conditions, prepare the wiring as follows: 1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2.
gas leak check electrolux 28 27 electrolux electrical work Gas leak check When using the vacuum pump For method of using a manifold valve, refer to its operation manual. 1. Completely tighten the flare nuts, A, B, C, D, connect the manifold valve charge hose to a charge port of the low-pressure valve on the gas pipe side. 2. Connect the charge hose connection to the vacuum pump. 3. Fully open the handle Lo of the manifold valve. 4. Operate the vacuum pump to evacuate.
29 electrolux operation test preparing the device for operation electrolux 30 Operation test Preparing the device for operation Perform test operation after completing gas leak check at the flare nut connections and electrical safety check. 1. Contact a specialist to install the device. 2. Guarantee that the unit is appropriately fastened and complies with all of the aforementioned safety norms. 3. Before operating the air conditioner, ensure that the air filter is installed correctly. 4.
product description electrolux 32 31 electrolux product description Product description Display panel (indoor unit) 1 Front panel frame 2 Front panel 13 OPERATION 3 Air filter 4 5 6 7 8 9 (inside front panel) Horizontal airflow grille Vertical airflow grille Temperature sensor (inside front panel) Panel Infra-red signal receiver Drain hose connector and refrigerant gas connector Remote control 10 11 Connector cable 12 Detection valve 13 Drain hose and refrigerant This lamp illuminates when the air c
remote control electrolux 34 33 electrolux remote control Remote control Remote control operation 1. Operating Mode: AUTO, COOL, DRY, HEAT(Cooling only model without), and FAN. 2. Timer Setting Function in 24 hours. 3. Indoor Setting Temperature Range : 17。C~30。C. 4. Full function of LCD (Liquid Crystal Display). REMOTE CONTROLLER SPECIFICATIONS Rated voltage 3V Lowest of voltage of CPU emiting signal 2,0 V Transmission distance 8 m* Environment When should the batteries be replaced 1.
remote control description electrolux 36 35 electrolux remote control description Remote control description ON/OFF: Operation starts when this button is pressed and stops when this button is pressed again. 2 MODE: Each time you push the button, a mode is selected in a sequence that goes from AUTO, COOL*, DRY, HEAT and FAN, as the following figure indicates: AUTO COOL DRY HEAT* FAN 1 * Note: Only for heating and cooling models. 3 SWING: Used to stop or start horizontal louver auto swing feature.
lcd display indicators electrolux 38 37 electrolux remote control description LCD display indicators 1 11 TURBO*: Active/Disable TURBO function. If pushing more than 2 seconds, the SELF CLEAN function will be activated, pushing more than 2 seconds again to disable(depending on models).During the heating operation(only when the setting mode is HEAT),press this button and the unit will operate at a setting temperature of 8°C.The display window of indoor unit will display FP.
39 electrolux how the air conditioner works how the air conditioner works electrolux 40 How the air conditioner works Auto operation Ensure the unit is plugged in and power is available. The OPERATION indicator on the display panel of the indoor unit starts flashing. 1. Press the MODE button to select Auto. 2. Press the UP/DOWN button to set the desired temperature. The temperature can be set within a range of 17°C~ 30°C in 1°C increments. 3. Press the ON/OFFbutton to start the air conditioner. Note: 1.
41 electrolux how the air conditioner works Timer operation Press the TIMER ON button can set the auto-on time of the unit. Press the TIMER OFF button can set the autooff time of the unit. To set the Auto-on time: 1. Press the TIMER ON button. The remote controller shows TIMER ON, the last Auto-on setting time and the signal "h" will be shown on the LCD display area. Now it is ready to reset the Auto-on time to START the operation. 2. Push the TIMER ON button again to set desired Auto-on time.
how the air conditioner works electrolux 44 43 electrolux how the air conditioner works COMBINED TIMER (Setting both ON and OFF timers simultaneously) TIMER OFF → TIMER ON (On → Stop → Start operation) This feature is useful when you want to stop the air conditioner after you go to bed, and start it again in the morning when you wake up or when you return home. Example: To stop the air conditioner 2 hours after setting and start it again 10 hours after setting. 1. Press the TIMER OFF button. 2.
how to use the indoor unit electrolux 46 45 electrolux how the air conditioner works How to use the indoor unit Clean-air function (optional) Improving the quality of indoor air is one of the purposes of an air conditioner. This air conditioner is equipped with ionizer or Plasma Dust Collector(Depending on specific configuration of the model). With the anions generated by Ionizer, the air circulation of the air conditioner fills the room with refreshing, natural and healthy air.
47 electrolux how to use the indoor unit manual operation (without remote control) electrolux 48 Manual operation (without remote control) Press the SWING button on the remote controller. To stop the function, press the SWING button again. Press AIR DIRECTION button to lock louver in desired position. The AIR DIRECTION and SWING buttons will be disabled when the air conditioner is not in operation (including when the TIMER ON is set).
maintenance electrolux 50 49 electrolux maintenance Maintenance then dry. 6. Clean the support frame using a vacuum cleaner or water. After, dry for a couple of hours or until dry. 7. Insert the fresh air filter in its original place. 8. Insert the high part of the air filter (fresh air filter + Support frame) again in the unit keeping in mind that the outside border (right and left) are lined up correctly, now place the whole filter in the initial position.
51 electrolux operation tips operation tips electrolux 52 Operation tips The following events may occur during normal operation. Protection of the air conditioner. Compressor protection The compressor can't restart for 3 minutes after it stops. Anti-cold air (Cooling and heating models only) The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached. 1. When heating has just starting. 2.
technical specifications electrolux 54 53 electrolux solutions for problems Solutions for problems Technical specifications If your air conditioner malfunctions, check the following information to find solutions or probable causes of the failure. Do not try to repair the unit by yourself, if these solutions do not solve the failures; call your local service repair team. HEAT AND COOL MODELS Poor Equipment performance 1. The air outlet or inlet in the exterior part is obstructed. 2.