User manual

N 560-568 mm
115 mm
20
mm
442 mm
180
mm
A 595
mm
N 600
mm
A 592 mm
A 567
mm
N min.
550 mm
~50 mm
A A
B
3. Use a minimum of 2 screws to attach
the oven on the 2 sides (A).
When installing next to a wood-fuelled
boiler, a heat-proof and heat-insulating
plate must be mounted at the height
of the appliance and at least 30 cm
deep.
A B
A
min. 20 mm
10
mm
20 mm
12.4 Electrical connection
WARNING!
If service is required always
disconnect the appliance from
the power supply.
Use a power cable of H05VV-F or higher.
Install the appliance with a socket supply
line. If there is no socket supply line, the
fixed home electrical system must include
an isolating device with at least a 3 mm-
contact separation to enable a
simultaneous and all-pole cut off from the
mains (according to NIN SEV 1000). The
customer must have a socket for the
electrical connection that is accessible
and outside the coordination room. The
length of the connection cable must be
approximately 120 cm with lines
connected directly to the mains.
Only a qualified person can
connect the appliance to the
electricity supply.
1. Do the electrical connections as in the
connection illustration.
Phase definitions: L1, L2 (or R, S).
Voltage: 400V
L2
L1PE
400V 2 ~
400V
1 2 3
45
2. Secure the cable grip.
1
2
ENGLISH