User manual

D
E
F
2. Put the connection cable into the
supplied rings (E).
This is to prevent the cable from
rubbing against the drawer. The
connection cable is on the housing
side.
3. Install the cable grip (F).
4. Connect the terminal as in the
illustration.
5. Put the cable into the strain relief
clamp.
6. Close the mains terminal cover.
7. Do the electrical connections as in the
connection illustration.
Phase definitions: L1, L2, L3 (or R, S,
T).
Voltage: 400V
L2
L3
400V
L1PE L2
400V
L1PE
1 2 3
45
1 2 3
45
400V 2N~
400V
400V
400V 3N~
N N
8. Secure the cable grip.
13.4 Electrical connection with
the hob
You can connect the oven to an
independent hob from the current range of
Electrolux and AEG hobs. You can
purchase the necessary connection cable
separately:
AK - EB / GKTC (S) 1 m for ceramic
hobs.
AK - EB / GKTCi (S) 1 m for induction
hobs.
The hob connection socket is at the top of
the oven cabinet.
14. ENERGY EFFICIENCY
14.1 Product Fiche and information according to EU 65-66/2014
Supplier's name Electrolux
Model identification
EBSL4CN
EBSL4SP
Energy Efficiency Index 81.2
Energy efficiency class A+
Energy consumption with a standard load, conven-
tional mode
1.09 kWh/cycle
Energy consumption with a standard load, fan-
forced mode
0.69 kWh/cycle
ENGLISH
25