Operation Manual

10 electrolux Installation
EN
Hood body installation
Before attaching the hood body, tight-
en the two screws Vr located on the
hood body mounting points.
Hook the hood body onto the screws
12a.
Fully tighten support screws 12a.
Adjust screws Vr to level the hood
body
Connection in Ducting Version
When installing the ducting version, con-
nect the hood to the chimney using either
a exible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
To install a ø 150 pipe
To install the dumper 10
Fix the pipe in position using sufcient
pipe clamps (not supplied).
To install a ø 120 pipe
To install a ø 120 mm air exhaust con-
nection, insert the reducer ange 9 on
the dumper 10.
Fix the pipe in position using sufcient
pipe clamps (not supplied).
Remove any activated charcoal lters.
Connection in Recycling Version
Insert the connection extension pieces
laterally 14.1 in connec-tion 15.
Insert the Connector 15 into the
Support bracket 7.3 and x it with a
screw.
Make sure that the outlet of the exten-
sion pieces 14.1 is hori-zontally and
vertically aligned with the chimney out-
lets.
Connect the air outlet connection 15
to the hood body outlet using either
a exible or rigid pipe ø 150 mm, the
choice of which is left to the installer.
Ensure that the activated charcoal l-
ters have been inserted.








