User manual

7GB
Mounting the hood body
Before attaching the hood body, tighten the two
screws Vr located on the hood body mounting
points.
Hook the hood body onto the screws 12a
Fully tighten support screws 12a
Adjust screws Vr to level the hood body.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the chimney using either a flexible or rigid
pipe ø 150 or 120 mm, the choice of which is left to the installer.
To install a ø 120 mm air exhaust connection,
insert the reducer flange 9 on the hood body
outlet.
Fix the pipe in position using sufficient pipe
clamps (not supplied).
Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
Put connection 15 into the connection support 7.3.
Insert the connection extension pieces laterally 14.1
in connection 15.
Make sure that the outlet of the extension pieces
14.1 is horizontally and vertically aligned with the
chimney outlets.
Connect the air outlet connection 15 to the hood
body outlet using either a flexible or rigid pipe ø 150
mm, the choice of which is left to the installer.
Ensure that the activated charcoal filters have been
inserted.
12a
Vr
9
ø 120ø 150
ø 150
14.1
15