MAINTENANCE
Grease filters
CLEANING METAL SELF- SUPPORTING GREASE FILTERS
Alarm signal reset
Switch off the lights and extractor motor.
Press button T3 for at least 3 seconds, until the
leds start to flash.
Cleaning the filters
The filters must be cleaned every 2 months of
operation, or more frequently for particularly
heavy usage, and can be washed in a dishwasher.
Remove the filters one at a time by pushing them
towards the back of the group and pulling down
at the same time.
Wash the filters, taking care not to bend them.
Allow them to dry before refitting.
When refitting the filters, make sure that the
handle is visible on the outside.
Activated charcoal filter (Recirculation version)
REPLACING THE ACTIVATED CHARCOAL FILTER
Alarm signal activation
In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a later
date. Turn the Lights and the suction Motor off.
Disconnect the Hood using the Main switch or the double-pole switch on the mains power supply.
Restore the connection by pressing and holding T1.
Release the button. All five LEDs are turned on
Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation:
LED flashes twice - Activated charcoal filter saturation alarm ENABLED
LED flashes once - Activated charcoal filter saturation alarm DISABLED