User manual

8
Remove the telescopic chimney support M by
unscrewing the side screws R (one on each side - these
screws must be kept). Fig. 6.
Remove the air pipe L from the telescopic chimney
support M; to do this, unscrew the four screws (Ø 2,9 x
9,5 mm) fixing the air pipe to the support (these screws
must be kept). Fig. 6.
Fit the telescopic chimney support to the wall, at a point
close to the ceiling. The telescopic chimney support has
a reference mark P, which must coincide with the line
that you have already drawn on the wall. Fig. 6.
Using a pencil, mark the two holes required to fix the
support, and drill the holes (Ø 8 mm). Fig. 6.
Insert two plugs and fix the telescopic chimney support
M using 2 screws size (5x45 mm). Fig. 6.
During installation the plug must not be connected to
the power supply.
Select the hood operating mode
Extractor operation
Fix the 150 mm diameter ABS pipe to the hood outlet
and ensure that the other end discharges into the open
air.
Filter operation
If the connector ring has not yet been installed, it must
be fitted at this point (Q in Fig. 7, bayonet connector).
Turn it in a clockwise direction and fix it to the air pipe
L using a screw. Insert the air pipe into the telescopic
chimney support and fix it with four screws (Ø 2,9 x 9,5
mm). Fig. 7.
Fix the 150 mm diameter ABS pipe to the hood outlet,
and connect it to the air pipe connector ring.
For both versions:
The hood can now be connected to the power supply.
If a gas non-return valve has been installed or is required,
ensure that it opens and closes properly.
Fix the top part the telescopic outlet pipe to the relative
support, using the two 3 mm dia x 9 mm screws R. Fig. 6.
Slide the bottom part of the telescopic outlet pipe
downward until it rests in its housing on the top of the
hood.
Replace the grease filters.
R
R
R
R
M
M
L
P
Q
L