User manual

4
1. Control panel
2. Operating light
3. Grease filters
Standard accessories included:
Screws for mounting
Template for wall mounting
No return valve (mounted on air outlet)
Mounting of grease filters
Attention! The grease filters are supplied not
mounted and packed in order to avoid damages
during transport of the hood.
Fit the pins of the filter on the slots of the grease
filter housing (a), then use the handles of the
filter to lock them (b).
Dismount the filter the opposite way.
Pull the handles backwards (c) to loosen the
filter (d) (Fig. 1).
Function
The hood may be used as follows:
- Exhausting version
- Recycling version
Attention! The Cooker hood is ready to be used for
air recycling (carbon filter already mounted in
place).
Exhausting version
The air is vented outdoors by a 150 mm duct
which must be connected to connecting ring
with no return valve on top of the motor
package.
The hood cannot be connected to
flues of other appliances that run
on energy sources other than
electricity. Please, keep to the provisions of official
directives regarding the question of fumes
discharge.
Recycling version
The air is filtered through a carbon filter and
recirculated into the room through the top sides of
the chimney (Fig. 2).
This version is used when there is no exhaust duct
for venting outdoors or when it is impossible to
install one.
Description of the appliance
Fig. 1
Fig. 2
1
2
3