User manual

25
connect duct and cables and then mount again the chimney.
3.4 GENERAL WARNING
The pipe must be heat, flame and corrosionproof. The producer strongly advises against the
use of reducers or pipes with smaller diameter to the hood outlet pipe. Also flexible aluminium
pipes are not recommended because performance is strongly diminished.
The end part of the pipe, on the outside of the hole on the wall, must be of such a shape to
avoid rain, gusts of wind or other foreign bodies getting into the pipe. Should there be any
doubt, contact anyone specialising in the installation of gas or ventilation system.
4 ELECTRICAL CONNECTION
4.1 WARNING
The electrical connection can only be carried out by qualified professional personnel, using
standard material and state of the art installation methods. The manufacturer declines any
responsibility for installations carried out by unskilled persons and for installations which are
not in conformity with the standard norms concerning electrical safety (both concerning
methods and materials).
4.2 ELECTRICAL TECHNICAL DATA
The electrical technical data are visible inside the hood after the removal of the grease filters.
4.3 CONNECTION TO THE POWER SUPPLY
The flexible feed cable supplied is already connected internally and emerges from the hood
near the air outlet duct.
It is possible to effect two types of electric installation:
fixed installation;
installation by means of plug on a socket.
4.4 BEFORE ELECTRICAL INSTALLATION
Before connection you must:
check that the electrical data indicated are in conformity with the main voltage and
frequency values of the building where the hood is to be installed;
check that the building is fitted with electric safety systems to protect against short circuits
and electric shock systems, according to the laws in force;
install an electric socket (or connection point) with a bipolar switch, which has contacts
with an opening of at least 3 mms;
if it is intended to install the hood with a plug, it is necessary that you have access to the
plug.
always turn off the main voltage supply by means of the bipolar switch before connecting
and switch on again only when connections have been completed, tested and are safe.