User manual

30
Mounting under cupboard
Make the holes on the bottom of the cupboard,
using the drilling template (Fig. 7).
From inside the cupboard, insert the 4 supplied
screws and tighten them in the appropriate holes
on the appliance.
Exhausting mode
Connect the air outlet to the smoke exhaust hose
Open the suction grid (Fig. 12).
Check that the selection lever for evacuation/
recycle is in the position A - external evacuation.
(Fig. 8).
Refit the suction grid.
Recirculation mode (with carbon
filter)
The air outlets D (Fig. 2) must be shut.
Open the suction grid (Fig. 12).
Check that the selection lever for evacuation/
recycle is in the position : F - recycle (Fig. 8)
Fit carbon filter first rearwards on the proper
seats.
Then fix frontwards the carbon filter using hooks
C (Fig. 9)
Refit the suction grid.
Using the hood
Speed regulation
The hood is provided with two motors with three
speeds plus a position for intensive operation. For
the best performance, we recommend using the
low speeds in normal conditions and the high
speeds or intensive in particular cases of strong
odour and vapour concentration.
We recommend starting up the hood a few minutes
before cooking and keeping it running until all the
odours have been eliminated.
C
C
Fig. 9
F
Fig. 8
A
A
Fig. 10
0 I 0 I 2 3
Fig. 7