Electrical connection (not for UK)
Safety warnings for the electrician
Before connecting the appliance to the power
supply, check that the voltage indicated on the
rating plate corresponds to the mains power supply
available. Appliances fitted with a plug can be
connected to any standard power socket within
easy access. Should it be necessary to provide a
fixed connection, the hood must only be installed by
an electrician authorised by the local electricity
board. When installing, an omnipolar disconnector
with a distance of at least 3 mm between contacts
must be provided.
Fixed connection of the appliance must only be
carried out by an authorised electrician.
Electrical connection for UK only
WARNING: DOUBLE INSULATED
DO NOT EARTH
Electrical Requirements
Any permanent electrical installation must comply
with the latest I.E.E. Regulations and local
Electricity Board regulations. For your own safety
this should be undertaken by a qualified electrician
e.g. your local Electricity Board, or a contractor
who is on the roll of the National Inspection
Council for Electrical Installation Contracting
(NICEIC) or a suitably competent person.
Electrical Connection
Before connecting to the mains supply ensure that
the mains voltage corresponds to the voltage on the
rating plate inside the cooker hood.
This appliance is fitted with a 2 core mains cable
and must be permanently connected to the
electricity supply via a double-pole switch having
3mm minimum contact gap on each pole. A
Switched Fuse Connection Unit to BS1363 Part 4,
fitted with a 5 Amp time delay fuse, is a
recommended mains supply connection accessory
to ensure compliance with the Safety Requirements
applicable to fixed wiring instructions.
This appliance conforms to BS 800: 1988 and EEC
Directive No. 78 308 regarding suppression of
radio and television interference.
Safety warnings for the electrician
The following is valid in Ireland only:
- the wire which is coloured blue must be
connected to the terminal which is marked with
the letter N,
- the wire which is coloured brown must be
connected to the terminal which is marked with
the letter L.