User manual
Electric sup‐
ply:
220-240 V ~ 50-60 Hz
Appliance cat‐
egory:
II2H3+
Gas connec‐
tion:
R 1/2"
Appliance
class:
3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Triple Crown 3,7 1,4 135
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Triple
Crown
3,8 1,4 98 276 271
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification EGC3313NOK
Type of hob Built-in hob
Number of gas burners 1
Energy efficiency per gas burner
(EE gas burner)
Centre Rear - Triple Crown 55.1%
Energy efficiency for the gas hob
(EE gas hob)
55.1%
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of
energy - General
10.2 Energy saving
• Before use, make sure that the burners and pan supports are assembled correctly.
• Use cookware with diameters applicable to the size of burners.
• Center the pot on the burner.
• When you heat up water, use only the amount you need.
• If it is possible, always put the lids on the cookware.
www.electrolux.com18