User manual

9.2 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Rapid 52
Auxiliary 28
9.3 Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 2,9 kW
Gas replacement: G30 (3+) 28-30 mbar = 269 g/h
G31 (3+) 37 mbar = 264 g/h
Electric supply: 220-240 V ~ 50/60 Hz
Appliance category: II2H3+
Gas connection: R 1/2"
Appliance class: 3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Rapid 2,9 0,75 120
Auxiliary 1,0 0,33 70
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Rapid 2,7 0,75 86 196 193
Auxiliary 1,0 0,33 50 73 71
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification EGC3322NOK
Type of hob Built-in hob
Number of gas burners 2
Energy efficiency per gas burner
(EE gas burner)
Centre rear - Rapid 59.4%
Centre front - Auxiliary not applicable