User manual

min 30 mm
60 mm
b
a
min 5 mm
(max 150 mm)
A. Removable panel
B. Space for connections
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
9. TECHNICAL DATA
9.1 Hob dimensions
Width 594 mm
Depth 510 mm
9.2 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Rapid 52
Semi-rapid 32
9.3 Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 7,15 kW
Gas replacement: G30 (3+) 28-30 mbar = 502 g/h
G31 (3+) 37 mbar = 493 g/h
Electric supply: 220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3
amp cartridge fuse
Appliance category: II2H3+
Gas connection: R 1/2"
Appliance class: 3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Rapid 2,2 0,95
Semi-rapid 1,65 0,55
ENGLISH 17